Aims: Previous DREAM studies demonstrated the safety and efficacy of the CE marked MD-Logic closed-loop system (DreaMed GlucoSitter) in different settings for overnight glycaemic control. The present study aimed to evaluate the system for day and night use for 60 hours during the weekend at home compared to sensor-augmented pump (SAP) therapy in participants with type 1 diabetes.
Methods: This was a prospective, multicentre, crossover, controlled study (clinicaltrials.gov NCT01238406). All participants were connected in randomized order for one weekend to SAP therapy or the MD-Logic System. In the intervention arm only, the amount of carbohydrate was entered into the bolus calculator; the rest of insulin delivery was automated and wireless via a tablet computer. The primary endpoint was percentage of glucose values between 70 and 180 mg/dL.
Results: The ITT population comprised 48 (19 males, 29 females) adolescents and adults experienced in sensor use: (median, [IQR]): age, 16.1years [13.2-18.5]; diabetes duration, 9.4 years [5.0-12.7]; pump use, 5.4 years [3.1-9.4]; HbA1c, 7.6% [7.0-8.1]. A significant increase in the percentage of time within target range (70-180 mg/dL) (66.6% vs 59.9%, P = 0.002) was observed with the closed-loop system vs control weekends with unchanged percentage of time below 70 mg/dL (2.3% vs 1.5%, P = 0.369). Mean weekend glucose level per participant was significantly lower (153 [142-175] vs 164 [150-186] mg/dL, P = 0.003). No safety signals were observed.
Conclusions: The MD-Logic system was safe and associated with better glycaemic control than SAP therapy for day and night use. The absence of remote monitoring did not lead to safety signals in adapting basal rates nor in administration of automated bolus corrections.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/dom.13585 | DOI Listing |
Front Physiol
January 2025
Departamento de Anatomía, Facultad de Medicina, Universidad Nacional Autónoma de México, Ciudad de México, Mexico.
Introduction: Access to electric light has exposed living organisms to varying intensities of light throughout the 24 h day. Dim light at night (DLAN) is an inappropriate signal for the biological clock, which is responsible for the circadian organization of physiology. During the gestational period, physiological adaptations occur to ensure a successful pregnancy and optimal fetal development.
View Article and Find Full Text PDFNeurobiol Sleep Circadian Rhythms
May 2025
Division of Geriatrics, University of São Paulo Medical School, São Paulo, Brazil.
Background: Although sleep duration and sleep-related breathing disorders were associated with dementia previously, few studies examined the association between circadian rhythm association and cognitive status.
Objective: We aimed to investigate the association of rest and activity rhythm with cognitive performance in older people with cognitive complaints and less education.
Methods: Activity rhythm was evaluated with wrist actigraphy in 109 community-dwelling older people with cognitive complaints without diagnosed dementia.
Int J Sport Nutr Exerc Metab
January 2025
Centre for Sport Research, Institute of Physical Activity and Nutrition, Deakin University, Geelong, Australia.
Evening consumption of a whey protein rich in the amino acid tryptophan, alpha-lactalbumin (ALAC), has previously shown to benefit sleep-particularly among poor sleepers. Given trained populations often experience sleep difficulty, this study investigated whether evening supplementation of ALAC would influence sleep outcomes, mood, and next-day cognitive performance within a trained population with sleep difficulties. Nineteen trained participants (females, n = 11) with sleep difficulties (Athlete Sleep Screening Questionnaire: 8.
View Article and Find Full Text PDFNeurourol Urodyn
January 2025
Cardiovascular Research Institute, Yokohama City University Graduate School of Medicine, Yokohama, Kanagawa, Japan.
Aims: To investigate the relationship between nocturia and values measured using a novel multifunctional portable urine-measuring device.
Methods: Thirty-five older men with nocturia and/or high-normal or high blood pressure were enrolled to record measurements on one full day (24 h) and two nights using the portable device during urination. Participants used a semi-conical cup with a small hole equipped with a conductivity sensor, temperature sensor, and timer to measure urine volume, salt content, urine temperature, and urination speed.
J Exp Zool A Ecol Integr Physiol
January 2025
Department of Life Sciences and Biotechnology, University of Ferrara, Ferrara, Emilia-Romagna, Italy.
In the wild, stressors occur with varying likelihood throughout the day, leading animals to evolve plastic stress responses that exhibit circadian rhythmicity. In mammals, studies have revealed that the circadian plasticity of stress response may differ with age. However, such developmental effects have been largely overlooked in other vertebrate groups.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!