A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

First-in-man pulmonary artery stenting in children using the Bentley® BeGrow™ stent system for newborns and infants. | LitMetric

Background: Stent implantation into growing vessels is a common treatment option in infants and children with congenital heart disease (CHD) and corresponding vessel lesions. After stent implantation in small children, repetitive stent redilations are frequently necessary to accommodate for somatic growth. Until now, all available stents have limited final expansion diameters.

Material And Results: The new Bentley BeGrow™ stent system for newborns and infants is a L605 cobalt‑chromium, pre-mounted, balloon expandable stent, which is compatible with a 4 French sheath and 0.014 inch guide wire thus allowing implantation in small vessels (4-6 mm). It offers a new, unique stent design that allows post-dilation steps up to Ø11.5 mm. While re-dilating up to Ø11.5 mm this new stent maintains radial force and shows uniform expansion with only minimal foreshortening. Predetermined breaking points allow the stent struts to break in a controlled manner when exceeding a diameter of 11.5 mm. Residual radial force maintains even after stent opening due to spiral arrangement of the predetermined breaking points. The 2 first-in-man pulmonary artery stent implantations in a newborn with univentricular circulation and a toddler with biventricular circulation are reported as part of the currently performed licencing trial (ClinicalTrials.govNCT03287024).

Conclusion: The low-profile BeGrow™ stent system offers new treatment options for transcatheter stent implantations in newborns and infants. In our first experience, it can be effectively implanted. Longer follow-up will evaluate multiple, stepwise redilations and controlled stent strut breakage, which have the potential to accommodate for somatic vessel growth and/or subsequent implantation of larger stents.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijcard.2018.11.029DOI Listing

Publication Analysis

Top Keywords

stent
14
begrow™ stent
12
stent system
12
newborns infants
12
first-in-man pulmonary
8
pulmonary artery
8
system newborns
8
stent implantation
8
implantation small
8
accommodate somatic
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!