In this paper, the torsional stress effect on Giant Magneto-Impedance (GMI) was studied in Co-rich amorphous wires. The study, which was conducted in the context of the development of a current clamp based on GMI, considered torsion as a parameter of the influence of this sensor. Both diagonal, Z, and off-diagonal, Z, components of the impedance tensor were investigated. The samples were Co-rich wires with a 100 µ diameter. The wires were twisted positive and negative angles with respect to a reference position. For each component of the impedance, the intrinsic sensitivity and offset were measured as a function of the rotation angle. The results showed that the sensitivity of the diagonal component at a given working point slightly increased for angles between -90° to +90°, whereas the sensitivity was almost constant for the off-diagonal component at zero-field. The intrinsic offset in the diagonal configuration was almost unchanged for the rotation angles considered, whereas this offset increased in the off-diagonal configuration. Furthermore, the GMI ratio of Z was also measured as a function of the rotation angle for comparison purposes with known data. The maximum of this ratio was obtained for a rotation angle of about 50°.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6308677PMC
http://dx.doi.org/10.3390/s18124121DOI Listing

Publication Analysis

Top Keywords

rotation angle
12
sensitivity diagonal
8
diagonal off-diagonal
8
amorphous wires
8
measured function
8
function rotation
8
torsion stress
4
offset
4
stress offset
4
sensitivity
4

Similar Publications

Most sports and leisure activities involve repetitive movements in the upper limb, which are typically linked to pain and discomfort in the neck and shoulder area. Movement variability is generally expressed by changes in movement parameters from one movement to another and is a time-dependent feature of repetitive activities. The purpose of this study was to examine the effect of repeated movement-induced fatigue on biomechanical coordination and variability in athletes with and without chronic shoulder pain (CSP).

View Article and Find Full Text PDF

In response to the rotary ploughing equipment in the stubble land to implement protective operations, the stubble is large in number and strong in toughness, not easy to crush, resulting in rotary ploughing equipment to produce entanglement and increased resistance to rotary ploughing and other issues. In this study, researchers designed a bionic rotary tillage blade (B-RTB) based on the bionic structural equations of the Marmota claw. A straw-soil complex shear performance test was conducted to investigate the effect of straw on soil shear strength.

View Article and Find Full Text PDF

We realize a Laughlin state of two rapidly rotating fermionic atoms in an optical tweezer. By utilizing a single atom and spin resolved imaging technique, we sample the Laughlin wave function thereby revealing its distinctive features, including a vortex distribution in the relative motion, correlations in the particles' relative angle, and suppression of the interparticle interactions. Our Letter lays the foundation for atom-by-atom assembly of fractional quantum Hall states in rotating atomic gases.

View Article and Find Full Text PDF

Structure-Function Analysis of CYP105A1 in the Metabolism of Nonsteroidal Anti-inflammatory Drugs.

Biochemistry

January 2025

Division of Food Science and Biotechnology, Graduate School of Agriculture, Kyoto University, Sakyo-ku, Kyoto 606-8502, Japan.

CYP105A1 exhibits monooxygenase activity to a wide variety of structurally different substrates with regio- and stereospecificity, making its application range broad. Our previous studies have shown that CYP105A1 wild type and its variants metabolize 12 types of nonsteroidal anti-inflammatory drugs (NSAIDs). In particular, the R84A variant exhibited a high activity against many NSAIDs.

View Article and Find Full Text PDF

Purpose: To assess the effects of modifying head position and of static ocular counter-rolling (OCR) on abduction and adduction in saccadic eye movements using a head-mounted video-oculographic device.

Study Design: A clinical observational study.

Methods: The peak velocities and amplitude gains of visually guided 12° saccades were binocularly measured in 21 healthy volunteers with their heads in the upright vertical (0°) and horizontal (± 90°, bilateral side-lying) postures, and in 6 participants with their head positions bilaterally tilted by 30°.

View Article and Find Full Text PDF