Objective: The nonsteroidal anti-inflammatory drug (NSAID) diclofenac epolamine (DHEP) formulated as a topical patch has demonstrated efficacy and safety in the localized treatment of acute pain from minor strains, sprains and contusions, and for epicondylitis and knee osteoarthritis. The glycosaminoglycan heparin enhances the activity of topical NSAIDs formulated as a medicated plaster, even in the absence of any significant release of heparin. Therefore, DHEP plus, a new formulation of the DHEP medicated plaster containing a small amount of heparin sodium as excipient, has been developed.
Methods: We reviewed the pivotal and supportive studies of the clinical development program of the new patch and evaluated the role of heparin as an enhancer in the treatment of localized pain/inflammation of musculoskeletal structures, associated with post-traumatic and/or rheumatic conditions.
Results: The data was consistent with the concept that heparin increased the clinical activity of the DHEP plus medicated plaster versus the reference DHEP medicated plaster through improved bioavailability due to enhanced movement of diclofenac from the plaster. Both DHEP formulations have the same dissolution profile, indicating that heparin does not change the physical and chemical characteristics of the plaster. Permeation testing showed that heparin is not released from the DHEP plus medicated plaster. Efficacy studies showed that the DHEP plus medicated plaster was significantly more effective in reducing pain than the reference marketed DHEP medicated plaster.
Conclusions: The benefit/risk assessment of DHEP plus 180 mg medicated plaster is favorable, with a safety profile equal to placebo and improved efficacy over the reference marketed DHEP medicated plaster.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1080/03007995.2018.1551194 | DOI Listing |
Emerg Radiol
January 2025
Department of Orthopaedics, Institute of Clinical Sciences, Lund University, Lund, Sweden.
Purpose: To evaluate the rate of missed scaphoid fractures on follow-up computed tomography (CT) for suspected occult scaphoid fracture after normal radiography with residual radial-sided wrist pain.
Methods: In a retrospective analysis, wrist CT during a five-year period was analyzed. The CT examinations and radiological reports were re-evaluated.
J Dent
January 2025
Department of Prosthetic Dentistry, Center for Dental Medicine, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
Objectives: This clinical study aimed to evaluate the accuracy of digital and conventional implant impressions in a fully edentulous maxilla and mandible.
Methods: A 53-year-old edentulous patient with four maxillary and two mandibular implants was selected. Ten intraoral scans (IOS) and a conventional impression per jaw were taken.
Front Oral Health
December 2024
Department of Clinical Sciences, College of Dentistry, Ajman University, Ajman, United Arab Emirates.
BMC Oral Health
December 2024
Department of Oral Surgery, Universidad de Salamanca, Salamanca, 37007, Spain.
Background: Knowing the available dental space in a patient is crucial for orthodontists to develop a good treatment plan.
Objectives: To compare and evaluate the reliability, reproducibility, and accuracy of three measurement methods on models: conventional, mobile app, and digital software.
Materials And Methods: Maxillary and mandibular dental plaster models of 20 subjects with permanent dentition were analyzed.
J Clin Monit Comput
December 2024
Department of Critical Care, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.
Mitochondrial oxygen tension (MitoPO2) is a promising novel non-invasive bedside marker of circulatory shock and is associated with organ failure. The measurement of mitoPO2 requires the topical application of 5-aminolevulinc acid (ALA) to induce sufficient concentrations of the fluorescent protein protoporphyrin-IX within (epi)dermal cells. Currently, its clinical potential in guiding resuscitation therapies is limited by the long induction time prior to obtaining a reliable measurement signal.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!