Reliability of a multi-segment foot model in a neutral cushioning shoe during treadmill walking.

J Foot Ankle Res

1SoleScience Inc., Fowler Kennedy Sports Medicine Clinic, 3M Building, Western University, London, ON N6A 3K7 Canada.

Published: February 2019

Background: Detailed kinematics of the foot has been frequently reported on in the literature, specifically using various multi-segment foot models. It is important to identify the reliability of a multi-segment foot model in a population of mixed genders and activity levels, while walking in commonly used footwear. The main objective of this study was to investigate the between-day reliability and within-session variability of the Oxford Foot Model (OFM) while walking in a neutral cushioning shoe.

Methods: A 7-camera Vicon motion capture system was used along with 29 passive reflective markers, placed on the participant to examine the multi-segment foot kinematics of the left foot using the OFM. Windows were cut in New Balance 840 shoes following reports from a previous investigation to maintain shoe integrity during testing. Two walking sessions on separate days were collected for 12 healthy participants, with an average total of 22 gait cycles per day.

Results: ICCs ranged from 0.020 to 0.964 for between-day reliability, and within-session ICC values ranged from 0.268 to 0.985. Between-day ICC values of the relative measures (excursion and range of motion (ROM)) were higher than the absolute angle measures (angle at foot strike and peak angle). Largest differences were measured in the transverse plane, and the smallest differences in the sagittal plane. Bland-Altman plots revealed best agreement in the frontal and sagittal planes. SEM values ranged from 0.04 to 3.5 for the between-day reliability.

Conclusions: Between-day reliability and within-session variability were comparable to previous studies for adults walking barefoot and shod. This research demonstrates that the OFM can produce reliable data when applied to the assessment of a shod foot.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6236956PMC
http://dx.doi.org/10.1186/s13047-018-0301-2DOI Listing

Publication Analysis

Top Keywords

multi-segment foot
16
foot model
12
between-day reliability
12
reliability within-session
12
foot
9
reliability multi-segment
8
neutral cushioning
8
within-session variability
8
icc values
8
values ranged
8

Similar Publications

A valid novel ground reaction force distribution algorithm to determine midfoot kinetics of gait with a single force plate.

Gait Posture

December 2024

Marquette University, 1250 W. Wisconsin Ave, Milwaukee, WI 53233, United States; Shriners Children's Chicago, 2211 N. Oak Park Ave, Chicago, IL 60707, United States.

Background: Understanding midfoot joint kinetics is valuable for improved treatment of foot pathologies. Segmental foot kinetics cannot currently be obtained in a standard gait lab without the use of multiple force plates or a pedobarographic plate overlaid with a force plate due to the single ground reaction force (GRF) vector.

Research Question: Can an algorithm be created to distribute the GRF into multiple segmental vectors that will allow for calculation of accurate midfoot and ankle moments?

Methods: 20 pediatric subjects (10 typically developing, 10 with foot pathology) underwent multi-segment foot gait analysis using the Milwaukee Foot Model.

View Article and Find Full Text PDF

The effect of foot deformities on the interplay of forces within the foot: An analysis of multi-segment foot joint moments in cerebral palsy.

Gait Posture

December 2024

Amsterdam UMC location Vrije Universiteit Amsterdam, Rehabilitation Medicine, De Boelelaan 1117, Amsterdam, The Netherlands; Amsterdam Movement Sciences, Rehabilitation & Development, Amsterdam, The Netherlands; Amsterdam UMC location University of Amsterdam, Rehabilitation Medicine, Meibergdreef 9, Amsterdam, The Netherlands.

Background: Foot deformities are common in cerebral palsy (CP) and are likely caused by a disturbed interplay of forces in the foot. Evaluation of foot joint moments would therefore be highly relevant. However, kinetic foot models have not previously been applied to children with CP.

View Article and Find Full Text PDF

This dataset presents human foot joints kinematics and kinetics data during walking, classified by static foot posture, filling a gap in existing lower limb databases that lack data on foot joints beyond the ankle or on static posture data, despite its link to foot and lower limb pathologies. Kinematics were recorded using a three-dimensional mocap system, and kinetics through a pressure platform, employing a multi-segment foot model including the ankle, midtarsal and first metatarsophalangeal joint. The dataset contains 350 recordings of right foot joint angles and moments and contact pressures from 70 healthy subjects with varying static posture (highly pronated, highly supinated and normal).

View Article and Find Full Text PDF

Effect of Custom-Made Foot Orthotics on Multi-Segment Foot Kinematics and Kinetics in Individuals with Structural Hallux Limitus.

Sensors (Basel)

October 2024

KU Leuven, Musculoskeletal Rehabilitation Research Group, Department of Rehabilitation Sciences, Campus Brugge, Spoorwegstraat 12, 8200 Bruges, Belgium.

The first metatarsophalangeal joint (MTPJ) and the first ray are crucial in walking, particularly during propulsion. Limitation in this joint's sagittal plane motion, known as hallux limitus, can cause compensatory movements in other joints. Some studies assessed the impact of various foot orthoses designs on the foot biomechanics; however, a comprehensive understanding is lacking.

View Article and Find Full Text PDF

Reliability testing of an IMU-based 2-segment foot model for clinical gait analysis.

Gait Posture

October 2024

Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Germany.

Background: The one of the most commonly used reference system for clinical gait analysis is an optical motion capture system (OMC) using a multi-segment foot model. A time- and cost-efficient alternative could be an inertial measurement unit (IMU)-based systems. However, these are limited to a single segment approach for the foot and ankle.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?