AI Article Synopsis

  • The study investigates the effectiveness of using adipose tissue-derived microvascular fragments (ad-MVF) compared to the stromal vascular fraction (SVF) for prevascularizing tissue engineering scaffolds.
  • The researchers found that ad-MVF exhibited higher viability and resulted in better vascularization, cellular infiltration, and incorporation into host tissue when implanted in mice.
  • Overall, the findings suggest that ad-MVF-based prevascularization is superior to the conventional SVF approach, leading to improved outcomes in tissue engineering applications.

Article Abstract

Background: The seeding of scaffolds with the stromal vascular fraction (SVF) of adipose tissue is a common prevascularization strategy in tissue engineering. Alternatively, adipose tissue-derived microvascular fragments (ad-MVF) may serve as vascularization units. In contrast to SVF single cells, they represent a mixture of intact arteriolar, capillary and venular vessel segments. Therefore, we herein hypothesized that the ad-MVF-based prevascularization of scaffolds is superior to the conventional SVF single cells-based approach.

Results: SVF single cells and ad-MVF were enzymatically isolated from epididymal fat pads of green fluorescent protein (GFP) donor mice to assess their viability and cellular composition using fluorescence microscopy and flow cytometry. Moreover, collagen-glycosaminoglycan matrices (Integra®) were seeded with identical amounts of the isolates and implanted into full-thickness skin defects within dorsal skinfold chambers of GFP recipient mice for the intravital fluorescent microscopic, histological and immunohistochemical analysis of implant vascularization and incorporation throughout an observation period of 2 weeks. Non-seeded matrices served as controls. While both isolates contained a comparable fraction of endothelial cells, perivascular cells, adipocytes and stem cells, ad-MVF exhibited a significantly higher viability. After in vivo implantation, the vascularization of ad-MVF-seeded scaffolds was improved when compared to SVF-seeded ones, as indicated by a significantly higher functional microvessel density. This was associated with an enhanced cellular infiltration, collagen content and density of CD31/GFP microvessels particularly in the center of the implants, demonstrating a better incorporation into the surrounding host tissue. In contrast, non-seeded matrices exhibited a poor vascularization, incorporation and epithelialization over time.

Conclusions: The present study demonstrates that ad-MVF are highly potent vascularization units that markedly accelerate and improve scaffold vascularization when compared to the SVF.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6234670PMC
http://dx.doi.org/10.1186/s13036-018-0118-3DOI Listing

Publication Analysis

Top Keywords

svf single
12
scaffolds stromal
8
stromal vascular
8
vascular fraction
8
adipose tissue-derived
8
tissue-derived microvascular
8
microvascular fragments
8
vascularization units
8
single cells
8
cells ad-mvf
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!