Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Aim: Our goal was to investigate the effect of a global XYZ median beat construction and the heart vector origin point definition on predictive accuracy of ECG biomarkers of sudden cardiac death (SCD).
Methods: Atherosclerosis Risk In Community study participants with analyzable digital ECGs were included (n = 15,768; 55% female, 73% white, mean age 54.2 ± 5.8 y). We developed an algorithm to automatically detect the heart vector origin point on a median beat. Three different approaches to construct a global XYZ beat and two methods to locate origin point were compared. Global electrical heterogeneity was measured by sum absolute QRST integral (SAI QRST), spatial QRS-T angle, and spatial ventricular gradient (SVG) magnitude, azimuth, and elevation. Adjudicated SCD served as the primary outcome.
Results: There was high intra-observer (kappa 0.972) and inter-observer (kappa 0.984) agreement in a heart vector origin definition between an automated algorithm and a human. QRS was wider in a median beat that was constructed using R-peak alignment than in time-coherent beat (88.1 ± 16.7 vs. 83.7 ± 15.9 ms; P < 0.0001), and on a median beat constructed using QRS-onset as a zeroed baseline, vs. isoelectric origin point (86.7 ± 15.9 vs. 83.7 ± 15.9 ms; P < 0.0001). ROC AUC was significantly larger for QRS, QT, peak QRS-T angle, SVG elevation, and SAI QRST if measured on a time-coherent median beat, and for SAI QRST and SVG magnitude if measured on a median beat using isoelectric origin point.
Conclusion: Time-coherent global XYZ median beat with physiologically meaningful definition of the heart vector's origin point improved predictive accuracy of SCD biomarkers.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6400224 | PMC |
http://dx.doi.org/10.1016/j.compbiomed.2018.11.013 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!