Lateral flow immunoassays (LFIAs) have wide application in point-of-care testing, particularly in resource-poor settings. To achieve signal amplification in a gold nanoparticle-based lateral flow assay without an additional procedure or the need for complex fabrication, a new and simple method was developed for using a "stacking pad" configuration that adds an additional membrane between the conjugation pad and test pad to the conventional AuNP-based LFIA format. This design helps to accumulate the antibody and antigen on the stacking pad, hence extending the antigen/antibody binding interactions to enhance the test's detection sensitivity. With the enhanced lateral flow assay, as low as 1 ng/mL of Protein A and 15.5 ng/mL of C-reactive protein can be visualized with the naked eye. We also successfully applied the stacking pad system in the analysis of C-reactive protein in human serum and synovial fluid samples. These results suggest that this stacking pad LFIA can provide sensitive and on-site prognosis for detection in synovial fluid and serum samples in resource-limited settings.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6251899 | PMC |
http://dx.doi.org/10.1038/s41598-018-35694-9 | DOI Listing |
Micromachines (Basel)
January 2025
School of Engineering, Deakin University, 75 Pigdons Rd., Waurn Ponds, Geelong, VIC 3216, Australia.
The metal bipolar plate is a critical component of the hydrogen fuel cell stack used in proton exchange membrane fuel cells. Bipolar plates must have high accuracy micro-channels with a high aspect ratio () between the channel depth and the half periodic width to achieve optimal cell performance. Conventional forming methods, such as micro-stamping, hydroforming, and rubber pad forming, cannot achieve these high ARs given that in these processes, material deformation is dominated by stretch deformation.
View Article and Find Full Text PDFBiosens Bioelectron
March 2025
Nanobiointeractions&Nanodiagnostics, Istituto Italiano di Tecnologia (IIT), Via Morego, 30, 16163, Genova, Italy. Electronic address:
Lateral flow assays (LFA) are widely adopted in point-of-care diagnostics across a spectrum of applications, due to their simplicity of use and cost-effectiveness. However, in complex biological matrices (e.g.
View Article and Find Full Text PDFAnal Chim Acta
November 2024
State Key Laboratory of Food Science and Technology, Jiangnan University, Wuxi, 214122, China; School of Food Science and Technology, Jiangnan University, Wuxi, 214122, China; School of Life Science and Health Engineering, Jiangnan University, Wuxi, 214122, China; International Joint Laboratory On Food Safety, Jiangnan University, Wuxi, 214122, China.
Nat Commun
September 2024
Tianjin Institute of Industrial Biotechnology, Chinese Academy of Sciences, Tianjin, China.
The inversion of substrate size specificity is an evolutionary roadblock for proteins. The Duf4243 dioxygenases GedK and BTG13 are known to catalyze the aromatic cleavage of bulky tricyclic hydroquinone. In this study, we discover a Duf4243 dioxygenase PaD that favors small monocyclic hydroquinones from the penicillic-acid biosynthetic pathway.
View Article and Find Full Text PDFBiomimetics (Basel)
April 2024
Department of Micro/Nano Electronics, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China.
In this paper, we proposed a miniature quadrupedal piezoelectric robot with a mass of 1.8 g and a body length of 4.6 cm.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!