We have experimentally demonstrated a single-photodiode 112-Gbit/s 16-QAM transmission over 960-km standard single mode fiber with Kramers-Kronig (KK) detection and a sparse I/Q Volterra filter (VF). KK detection is used to mitigate the signal to signal beating interference. A novel I/Q VF based on dual-input real-valued Volterra series is proposed to overcome the constraints of non-linear distortions. Two conventional single-input real-valued VFs are employed as a contrast to prove the necessity of I/Q hybrid structure in I/Q VF when the system suffers from severe I/Q imbalance and crosstalk. The proposed I/Q VF brings nearly two order magnitude improvement in BER performance compared with the conventional linear equalizer for back to back case and doubles the transmission distance from 480 km to 960 km at the hard-decision forward error correction threshold of 3.8 × 10. To reduce the complexity of full I/Q VF, a simple ℓ regularization-based least mean square (LMS) algorithm is employed to identify the significant kernels and construct a sparse I/Q VF. Compared with full I/Q VF, the sparse I/Q VF reduces up to 58% complexity at 960 km while having the similar BER performance.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.26.024564DOI Listing

Publication Analysis

Top Keywords

sparse i/q
16
i/q
11
single-photodiode 112-gbit/s
8
112-gbit/s 16-qam
8
16-qam transmission
8
transmission 960-km
8
kramers-kronig detection
8
detection sparse
8
i/q volterra
8
volterra filter
8

Similar Publications

Traditional underwater polarization imaging methods can only provide clear degree of polarization (DOP) and intensity images of the object but cannot provide images of the polarization state of the object. This paper proposes a method to extract clear object information from turbid water in all four Stokes parameter (I, Q, U, and V) channels by using the full Stokes camera, enabling clear polarization state image reconstruction. The method utilizes multiple images from different angles to construct a low-rank and sparse matrix.

View Article and Find Full Text PDF

Ultrasound imaging with flexible transducers based on real-time and high-accuracy shape estimation.

Ultrasonics

April 2025

Department of Biomedical Engineering, Fudan University, Shanghai 200438, China; Key Laboratory of Medical Imaging Computing and Computer Assisted Intervention of Shanghai, Shanghai 200032, China. Electronic address:

Article Synopsis
  • Ultrasound imaging with flexible transducers needs precise shape geometry for effective beamforming, but traditional methods for shape estimation are costly in terms of computation time and often lack accuracy.
  • A new deep-learning method, FlexSANet, offers a fast and accurate approach by demodulating I/Q data and using a sparse processing mechanism to reduce estimation time.
  • Evaluations show that FlexSANet achieves high-quality imaging with minimal error in shape estimation (less than 1/8 wavelengths), and demonstrates promising clinical application potential with an estimation time of just 0.12 seconds.
View Article and Find Full Text PDF

An efficient nonlinear equalizer based on the pruning I/Q-joint deep neural network (DNN) is proposed and experimentally demonstrated to mitigate the nonlinearity in a photonics-assisted millimeter-wave (MMW) system with a high-order 256 quadrature-amplitude-modulation (QAM) format. Experimental findings reveal that implementing pruning on the I/Q-joint DNN can compress the computational overhead by 32% while accommodating 256-QAM E-band MMW transmission for a net throughput of 66.67 Gbps with 20.

View Article and Find Full Text PDF

Background: Laparoscopy has been widely adopted in elective abdominal surgery but is still sparsely used in emergency settings. The study investigated the effect of laparoscopic emergency surgery using a population database.

Methods: Data for all patients from December 2013 to November 2018 were retrieved from the NELA national database of emergency laparotomy for England and Wales.

View Article and Find Full Text PDF

Chronic pain after hand-assisted laparoscopic donor nephrectomy.

Br J Surg

May 2019

Department of Surgery, Division of Transplant Surgery, University Medical Centre Groningen, University of Groningen, Groningen, the Netherlands.

Background: Data on chronic pain after kidney donation are sparse. The aim of this study was to assess the incidence of chronic pain after hand-assisted laparoscopic nephrectomy.

Methods: Living kidney donors who donated between 2011 and 2017 at the University Medical Centre Groningen were included.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!