Accuracy of 3D surface scanners for clinical torso and spinal deformity assessment.

Med Eng Phys

Paediatric Spine Research Group, Institute of Health and Biomedical Innovation at Centre for Children's Health Research, Queensland University of Technology, Brisbane, Australia. Electronic address:

Published: January 2019

Externally visible deformities are cosmetic features of great concern for Adolescent Idiopathic Scoliosis (AIS) patients. Current assessment techniques for AIS do not fully encompass the external deformity. A non-invasive method capable of capturing superficial anatomy, such as 3D scanning, would enable better qualitative and quantitative evaluation of cosmesis. This study aimed to quantify the accuracy of commonly available scanners, in assessing posterior asymmetry in AIS. The technique of 3D surface deviation analysis was proposed as a suitable method for comparing the models created by each scanner. Eight plaster cast moulds manufactured to create braces for AIS patients were used as test samples. Four 3D scanners were selected: Solutionix RexScan CS+; Artec Eva; Microsoft Kinect V1; iPhone with 123D Catch App. These scanners were selected from those available as representative of a range of scanning technologies. Each cast was scanned and 3D models created. A simulated rib hump measurement was obtained and the surface-to-surface deviations between the Solutionix scan and all other scans were determined. The Solutionix scanner is a metrology scanner of very high quality and so it was selected as the reference. Surface-to-surface deviations were calculated in the positive and negative directions separately to specifically identify size and volume inaccuracies created by the scans. Surface deviations showed excellent agreement between the Solutionix and the Eva with deviations of +0.17 ± 0.17 mm (Eva regions larger) and -0.20 ± 0.32 mm (Eva regions smaller) (mean±SD). The Kinect showed lower agreement (+1.58 ± 1.50 mm and -0.58 ± 0.58 mm). The iPhone scans were not able to be scaled to the correct size, so were excluded. Rib hump measurements with all scanners were within clinical measurement variability (±4.9 deg) of the known values. These commercially available 3D scanners are capable of imaging torso shape in 3D and deriving clinically relevant external deformity measures. The non-invasive 3D topographic information provided can be used to improve assessment of torso shape in spinal deformity patients.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.medengphy.2018.11.004DOI Listing

Publication Analysis

Top Keywords

scanners clinical
8
spinal deformity
8
ais patients
8
external deformity
8
models created
8
scanners selected
8
rib hump
8
surface-to-surface deviations
8
eva regions
8
torso shape
8

Similar Publications

Diffusion weighted imaging (DWI) is used for monitoring purposes for lower-grade glioma (LGG). While the apparent diffusion coefficient (ADC) is clinically used, various DWI models have been developed to better understand the micro-environment. However, the validity of these models and how they relate to each other is currently unknown.

View Article and Find Full Text PDF

Kirsten Rat Sarcoma viral oncogene homolog (KRAS) is a frequently occurring mutation in non-small-cell lung cancer (NSCLC) and influences cancer treatment and disease progression. In this study, a machine learning (ML) pipeline was applied to radiomic features extracted from public and internal CT images to identify KRAS mutations in NSCLC patients. Both datasets were analyzed using parametric ( test) and non-parametric statistical tests (Mann-Whitney U test) and dimensionality reduction techniques.

View Article and Find Full Text PDF

Cognitive impairment affects memory, reasoning, and problem-solving, with early detection being critical for effective management. The amygdala, a key structure in emotional processing and memory, may play a pivotal role in detecting cognitive decline. This study examines differences in amygdala nuclei volumes in patients with varying levels of cognitive performance to evaluate its potential as a biomarker.

View Article and Find Full Text PDF

Objective: To quantitatively evaluate the accuracy of data obtained from liquid-interference surfaces using an intraoral 3D scanner (IOS) integrated with a compressed airflow system, so as to provide clinical proof of accuracy for the application of the compressed airflow system-based scanning head in improving data quality on liquid-interference surfaces.

Methods: The study selected a standard model as the scanning object, adhering to the "YY/T 1818-2022 Dental Science Intraoral Digital Impression Scanner" guidelines, a standard that defined parameters for intraoral scanning. To establish a baseline for accuracy, the ATOS Q 12M scanner, known for its high precision, was used to generate true reference values.

View Article and Find Full Text PDF

Introduction: Using digital technology, respectively the use of intraoral scanners has increased exponentially in recent years. Intraoral scanners have gained traction and widespread use in the field of dental prosthetics and orthodontics. While the use of these digital devices enables the detection of visible areas of error in order to allow clinicians to correct those areas immediately without a need of restarting the entire process from the beginning as it should be done in the conventional method and subsequent procedures.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!