A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Ratiometric Fluorescent Detection of Intracellular Singlet Oxygen by Semiconducting Polymer Dots. | LitMetric

Singlet oxygen (O) plays important roles in many biological processes. However, it is very difficult to detect O in the intracellular environment because of its relatively low concentration and short lifetime. Here, we developed a ratiometric probe based on semiconducting polymer dots (Pdots) that can sensitively detect O in live cells. An organic dye, singlet oxygen sensor green (SOSG), was doped in polyfluorene Pdots, and excitation energy was efficiently transferred from the polymer to the SOSG dye. Accordingly, the Pdots showed constant blue fluorescence as a reference, and increased green fluorescence upon singlet oxygen generation. The ratiometric response of Pdots was examined in the intracellular environment by in situ O generation with a photosensitizer and light irradiation. Both spectroscopic measurements and confocal imaging were performed to monitor intracellular O generation during photodynamic therapy using the Pdot probe. Our results indicate that the SOSG-doped Pdots are promising for intracellular O detection.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.analchem.8b04859DOI Listing

Publication Analysis

Top Keywords

singlet oxygen
16
semiconducting polymer
8
polymer dots
8
intracellular environment
8
intracellular
5
pdots
5
ratiometric fluorescent
4
fluorescent detection
4
detection intracellular
4
singlet
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!