A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development and validation of a robust multiplex serological assay to quantify antibodies specific to pertussis antigens. | LitMetric

Despite wide spread vaccination, the public health burden of pertussis remains substantial. Current acellular pertussis vaccines comprise upto five Bordetella pertussis (Bp) antigens. Performing an ELISA to quantify antibody for each antigen is laborious and challenging to apply to pediatric samples where serum volume may be limited. We developed a microsphere based multiplex antibody capture assay (MMACA) to quantify antibodies to five pertussis antigens; pertussis toxin, pertactin, filamentous hemagglutinin and fimbrial antigens 2/3, and adenylate cyclase toxin in a single reaction (5-plex) with a calibrated reference standard, QC reagents and SAS based data analysis program. The goodness of fit (R) of the standard curves for five analytes was ≥0.99, LLOQ 0.04-0.15 IU or AU/mL, accuracy 1.9%-23.8% (%E), dilutional linearity slopes 0.93-1.02 and regression coefficients r = 0.91-0.99. MMACA had acceptable precision within a median CV of 16.0%-22.8%. Critical reagents, antigen conjugated microsphere and reporter antibody exhibited acceptable (<12.3%) lot-lot variation. MMACA can be completed in <3 h, requires low serum volume (5μL/multiplex assay) and has fast data turnaround time (<1 min). MMACA has been successfully developed and validated as a sensitive, specific, robust and rugged method suitable for simultaneous quantification of anti-Bp antibodies in serum, plasma and DBS.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8864582PMC
http://dx.doi.org/10.1016/j.biologicals.2018.11.001DOI Listing

Publication Analysis

Top Keywords

pertussis antigens
12
quantify antibodies
8
pertussis
6
development validation
4
validation robust
4
robust multiplex
4
multiplex serological
4
serological assay
4
assay quantify
4
antibodies specific
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!