Background: Incisional heia is a frequent complication of midline laparotomy. The use of mesh in hernia repair has been reported to lead to fewer recurrences compared to primary repair. However, in Ventral Hernia Working Group (VHWG) Grade 3 hernia patients, whose hernia is potentially contaminated, synthetic mesh is prone to infection. There is a strong preference for resorbable biological mesh in contaminated fields, since it is more able to resist infection, and because it is fully resorbed, the chance of a foreign body reaction is reduced. However, when not crosslinked, biological resorbable mesh products tend to degrade too quickly to facilitate native cellular ingrowth. Phasix™ Mesh is a biosynthetic mesh with both the biocompatibility and resorbability of a biological mesh and the mechanical strength of a synthetic mesh. This multi-center single-arm study aims to collect data on safety and performance of Phasix™ Mesh in Grade 3 hernia patients.

Methods: A total of 85 VHWG Grade 3 hernia patients will be treated with Phasix™ Mesh in 15 sites across Europe. The primary outcome is Surgical Site Occurrence (SSO) including hematoma, seroma, infection, dehiscence and fistula formation (requiring intervention) through 3 months. Secondary outcomes include recurrence, infection and quality of life related outcomes after 24 months. Follow-up visits will be at drain removal (if drains were not placed, then on discharge or staple removal instead) and in the 1st, 3rd, 6th, 12th, 18th and 24th month after surgery.

Conclusion: Based on evidence from this clinical study Depending on the results this clinical study will yield, Phasix™ Mesh may become a preferred treatment option in VHWG Grade 3 patients.

Trial Registration: The trial was registered on March 25, 2016 on clinicaltrials.gov: NCT02720042 .

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6247668PMC
http://dx.doi.org/10.1186/s12893-018-0439-7DOI Listing

Publication Analysis

Top Keywords

phasix™ mesh
20
vhwg grade
16
mesh
12
grade hernia
12
multi-center single-arm
8
hernia repair
8
hernia patients
8
synthetic mesh
8
biological mesh
8
clinical study
8

Similar Publications

Introduction: The classic open ventral hernia repair provides excellent results in recurrences. However, wound complications are the Achilles heel for a good overall clinical outcome. Laparoscopic surgery is in general associated with less pain, better esthetic results, faster recovery, and lower incidence of wound complications.

View Article and Find Full Text PDF

To rest or not to rest after sacral colpopexy? Dispelling an old custom in the ERAS time.

Arch Gynecol Obstet

January 2025

Department of Gynaecology and Obstetrics, Fondazione Policlinico Universitario "A. Gemelli", Università Cattolica del Sacro Cuore, Rome, Italy.

Purpose: Despite the advent of the ERAS Program, recovery after urogynecological surgery is still a highly debated topic in clinical practice. The majority of gynecologic surgeons, in fact, continue to advise patients to home rest and to avoid lifting heavy objects after surgery. The aim of the present study was to verify the impact of a moderate-high physical activity and recovery after surgery on anatomical results after LSC, with a 2-year follow-up (FU).

View Article and Find Full Text PDF

Metallic biomaterials are extensively used in orthopedics and dentistry, either as implants or coatings. In both cases, metal ions come into contact with surrounding tissues causing a particular cell response. Here, we present a biofabricated tissue model, consisting of a hydrogel reinforced with a melt electrowritten mesh, to study the effects of bound and released metal ions on surrounding cells embedded in a hydrogel matrix.

View Article and Find Full Text PDF

Background: Minimally invasive esophagectomy (MIE) can lead to a severe complication known as recurrent laryngeal nerve paralysis (RLNP). Existing literature supports that recurrent laryngeal nerve (RLN) injury is the principal etiology of RLNP, a complication potentially mitigated through intraoperative neuromonitoring (IONM). In this study, we examined the comprehensive effectiveness of IONM during esophageal resection by performing a meta-analysis.

View Article and Find Full Text PDF

Aim: The aim of this literature review was to determine if a consensus could be reached on whether amblyopia treatment causes distress to patients and/or their guardians, and if so, establish the impact of this reported psychological distress upon paediatric patients and/or their parents/guardians.

Methods: A systematic review of the literature was conducted of all publications written in English. Search terms included both MeSH terms and alternatives related to amblyopia and psychological distress.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!