Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Entheses are regions where tendons and ligaments attach to bone, and are the primary target in seronegative and other diseases of the musculoskeletal (MSK) system. MRI has been widely used for visualizing features of inflammatory and degenerative MSK disease; however, normal tendons and entheses have short transverse relaxation times (T ), and show little or no signal with conventional clinical MRI pulse sequences, making it difficult to investigate their MR properties. In this study we examined the normal MR morphology of the cadaveric Achilles tendon and enthesis at 3 T using novel three-dimensional ultrashort echo time (3D UTE) Cones sequences, and at 11.7 T using conventional MRI sequences. We also studied the MR properties of the Achilles tendon and enthesis including T *, T , and magnetization transfer ratio (MTR). In addition, MT modeling of macromolecular proton fractions was investigated using 3D UTE Cones sequences at 3 T. Indentation testing was performed to investigate the mechanical properties of the tendons and entheses, and this was followed by histological examination. In total five specimens (<50 years) were investigated. On average, tendons and entheses respectively had T * values of 0.93 ± 0.48 ms and 2.77 ± 0.79 ms, T values of 644 ± 22 ms and 780 ± 55 ms, MTRs of 0.373 ± 0.03 and 0.244 ± 0.009 with an MT power of 1000° and frequency offset of 2 kHz, and macromolecular proton fractions of 18.0 ± 2.2% and 13.9 ± 1.9%. Compared with the tendon, the enthesis generally had a longer T *, a longer T , a lower MTR, and a lower macromolecular proton fraction as well as both a higher Young's modulus and stiffness. Results from this study are likely to provide a useful baseline for identifying deviations from the normal in seronegative arthritis and other disease of the entheses.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/nbm.4034 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!