High precision conformal radiotherapy requires sophisticated imaging techniques to aid in target localisation for planning and treatment, particularly when organ motion due to respiration is involved. X-ray based imaging is a well-established standard for radiotherapy treatments. Over the last few years, the ability of magnetic resonance imaging (MRI) to provide radiation-free images with high-resolution and superb soft tissue contrast has highlighted the potential of this imaging modality for radiotherapy treatment planning and motion management. In addition, these advantageous properties motivated several recent developments towards combined MRI radiation therapy treatment units, enabling in-room MRI-guidance and treatment adaptation. The aim of this review is to provide an overview of the state-of-the-art in MRI-based image guidance for organ motion management in external beam radiotherapy. Methodological aspects of MRI for organ motion management are reviewed and their application in treatment planning, in-room guidance and adaptive radiotherapy described. Finally, a roadmap for an optimal use of MRI-guidance is highlighted and future challenges are discussed.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1088/1361-6560/aaebcf | DOI Listing |
Sci Rep
January 2025
Department of Electrical and Electronics, Faculty of Engineering, Alberoni University, Kapisa, Afghanistan.
This study first proposes an innovative method for optimizing the maximum power extraction from photovoltaic (PV) systems during dynamic and static environmental conditions (DSEC) by applying the horse herd optimization algorithm (HHOA). The HHOA is a bio-inspired technique that mimics the motion cycles of an entire herd of horses. Next, the linear active disturbance rejection control (LADRC) was applied to monitor the HHOA's reference voltage output.
View Article and Find Full Text PDFEur J Orthop Surg Traumatol
January 2025
Duzce University, Düzce, Turkey.
Purpose: Blood loss and pain management are significant concerns in total knee arthroplasty (TKA). Tranexamic acid (TA) and cryotherapy have been used separately to address these issues, but their comparative effectiveness is not well studied. This study aimed to evaluate the efficacy of intravenous TA and cryotherapy in reducing blood loss and improving clinical outcomes after TKA.
View Article and Find Full Text PDFBackground: Total ankle replacement (TAR) has evolved in the last decade from a procedure rife with complication and failure to a promising alternative to arthrodesis. The ability to maintain ankle joint range of motion is showing great promise in patient-reported outcomes, postsurgical pain, as well as long-term sequalae of joint fusion. Although TAR can be performed via either an anterior or lateral approach both with their own sets of benefits and potential complications, the consensus seems to be that one is no better than the other when performed by high-volume surgeons.
View Article and Find Full Text PDFAm J Case Rep
January 2025
Department of Orthopedic Surgery, Sichuan Provincial People's Hospital, School of Medicine, University of Electronic Science and Technology of China, Chengdu, Sichuan, China.
BACKGROUND The management of unstable atlas fractures remains a subject of ongoing debate and controversy. The conservative surgical treatment commonly involves fusion, resulting in severe loss of cervical spine mobility, and a large incisions and extensive tissue dissection are required. We aim to introduce a novel concept and surgical approach for treating atlas fracture, one that involves minimizing trauma while maintaining mobility of the upper cervical spine without resorting to fusion.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Faculty of Science and Engineering, Saga University, Saga 840-8502, Japan.
Infrared array sensor-based fall detection and activity recognition systems have gained momentum as promising solutions for enhancing healthcare monitoring and safety in various environments. Unlike camera-based systems, which can be privacy-intrusive, IR array sensors offer a non-invasive, reliable approach for fall detection and activity recognition while preserving privacy. This work proposes a novel method to distinguish between normal motion and fall incidents by analyzing thermal patterns captured by infrared array sensors.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!