Natural radiation is a feature of the environment in which we live. One of the contributions of human exposure to ionizing radiation due to natural sources arises from gamma radiation. Therefore, present study was aimed to evaluate and map indoor gamma dose rate in Tehran. The corresponding annual effective dose (AED) and excess lifetime cancer risk (ELCR) were also calculated. All measurements were performed by a Geiger Muller detector in 43 dwellings in Tehran. The average indoor gamma dose rate in Tehran was appointed as 343.2 nGy/h. AED and ELCR were calculated as 2.4 mSv and 10.3 × 10-3, respectively. The evaluated indoor gamma dose rate and calculated AEDs and lifetime cancer risk were found higher than the world average value.

Download full-text PDF

Source
http://dx.doi.org/10.1093/rpd/ncy193DOI Listing

Publication Analysis

Top Keywords

indoor gamma
16
lifetime cancer
12
cancer risk
12
gamma dose
12
dose rate
12
gamma radiation
8
excess lifetime
8
rate tehran
8
elcr calculated
8
gamma
5

Similar Publications

Machine learning techniques for the prediction of indoor gamma-ray dose rates - Strengths, weaknesses and implications for epidemiology.

J Environ Radioact

December 2024

Radiation Epidemiology Branch, Division of Cancer Epidemiology and Genetics, National Cancer Institute, DHHS, NIH, Bethesda, MD, 20892-9778, USA; Faculty of Health and Life Sciences, Oxford Brookes University, Headington Campus, Oxford, OX3 0BP, UK. Electronic address:

We investigate methods that improve the estimation of indoor gamma ray dose rates at locations where measurements had not been made. These new predictions use a greater range of modelling techniques and larger variety of explanatory variables than our previous examinations of this subject. Specifically, we now employ three types of machine learning models in addition to the geostatistical, nearest neighbour and other earlier models.

View Article and Find Full Text PDF

Accurate assessment of the aging state of transformer oil-barrier insulation is crucial for ensuring the safe and reliable operation of power systems. This study presents the development of indoor accelerated thermal aging experiments to simulate the degradation of oil-immersed barrier insulation within transformers. A series of samples reflecting various aging states was obtained and categorized into six distinct groups.

View Article and Find Full Text PDF

Radiation doses received by humans in their dwellings - A baseline report on radionuclides exposure from construction materials used in Chennai, Tamil Nadu, India.

J Hazard Mater

December 2024

Unit of Research in Radiation Biology & Environmental Radioactivity (URRBER), P.G. & Research Department of Zoology, The New College (Autonomous), Affiliated to University of Madras, Chennai, Tamil Nadu 600 014, India. Electronic address:

Gamma-ray spectrometry was employed to assess the activity concentrations of primordial radionuclides (U, Th, and K) in various construction materials, including those used for building, roofing, furnishing, flooring, and plastering. The measured activity concentrations of the radionuclides ranged as follows: U (25 to 477 Bq kg), Th (below detection limit to 239 Bq kg), and K (285 to 1915 Bq kg). Based on these values, the materials were categorized in descending order of radioactivity threat as: Furnishing > Roofing > Building > Flooring > Plastering.

View Article and Find Full Text PDF

Concentration, pathogenic composition, and exposure risks of bioaerosol in large indoor public environments: A comparative study of urban and suburban areas.

Sci Total Environ

December 2024

Guangdong-Hong Kong-Macao Joint Laboratory for Contaminants Exposure and Health, Guangdong Key Laboratory of Environmental Catalysis and Health Risk Control, Institute of Environmental Health and Pollution Control, Guangdong University of Technology, Guangzhou 510006, China; Guangzhou Key Laboratory of Environmental Catalysis and Pollution Control, Guangdong Basic Research Center of Excellence for Ecological Security and Green Development, School of Environmental Science and Engineering, Guangdong University of Technology, Guangzhou 510006, China.

Biological contamination in larger indoor environments can lead to the outbreak of various infectious diseases. This study aimed to compare the pollution profiles and associated health risks of airborne microorganisms in different indoor settings between urban and suburban areas by culturing, sequencing, and toxicological evaluation. The results indicated that the average level of culturable bacteria was higher in urban areas (955 ± 259 CFU/m) compared to suburban areas (850 ± 85 CFU/m), with the highest concentrations found in the market (2170 ± 798 CFU/m) and gymnasium (2010 ± 300 CFU/m).

View Article and Find Full Text PDF

Tobacco (Nicotiana tabacum L.) plants were grown outdoors (N°46.07, E°18.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!