A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effect of different dry-polishing regimens on the intrapulpal temperature assessed with pulpal blood microcirculation model. | LitMetric

Objective: The aim of the study was to evaluate the effect of different dry-polishing regimens on the intrapulpal temperature assessed using a pulpal blood microcirculation model.

Materials And Methods: Eighty extracted human mandibular premolar teeth were used. Standardized class V cavity preparations were performed and were then restored. Teeth were divided into four main groups (n = 20): Fine polishing disc (SSF; 3M Sof-Lex, 3M ESPE, Minnesota); Super-fine polishing disc (SSS; 3M Sof-Lex); Spiral finishing wheel (SSW; 3M Sof-Lex); Enhance PoGo-One step diamond micro-polisher cup (EPO; Dentsply Sirona, Inc, Delaware). The main groups were divided: the low-load pressure (0.4N) and the high-load pressure (0.8N). The average change in intrachamber temperatures (Δt), from initial to highest, were measured.

Results: The highest temperature increase was recorded in SSF08 (9.55°C). The lowest value was recorded in EPO04 (1.9°C). SSS08, SSW08, and EPO08 demonstrated significantly higher Δt values than the low-load mode in SSS04, SSW04, and EPO04, respectively (P < .0001).

Conclusions: Temperature was the least affected by the diamond cup in both pressure modes, and it was also less affected by the spiral finishing wheel in the low-load mode than in the high-load mode. Fine and super-fine discs had the greatest effect on intrachamber temperatures.

Clinical Significance: The present study suggests intrachamber temperature can rise among different dry-polishing regimes. Dental practitioners should pay attention to dry-polishing regimens and pressures for reducing heat-related dental problems.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jerd.12442DOI Listing

Publication Analysis

Top Keywords

dry-polishing regimens
8
regimens intrapulpal
8
intrapulpal temperature
8
temperature assessed
8
assessed pulpal
8
pulpal blood
8
blood microcirculation
8
main groups
8
polishing disc
8
microcirculation model
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!