The cationic polyelectrolyte pDADMAC is widely used in biopharmaceutical industry as a flocculating agent to enhance clarification throughput and downstream filtration operations. Due to the possible toxicity, pDADMAC should be assessed for an acceptable residual level to ascertain the safety of the product to patients. The strong protein-polyelectrolyte interaction, however, can negatively affect sensitivity and accuracy of measurements. This paper reports on the application of size exclusion (SE) chromatography coupled to evaporative light scattering detector (ELSD) to the quantitative determination of pDADMAC in monoclonal antibody formulations and in process intermediates during downstream purification. The SE chromatography was performed under isocratic condition with a mobile phase consisting of 0.1% TFA in water (90%) and acetonitrile (10%) at a flow rate of 0.4 ml/min. A quantification limit (S/N = 10) of 0.85 ppm was achieved in sample matrix, which is sufficiently low for the trace analysis of this compound in protein-containing samples.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.biologicals.2018.11.002 | DOI Listing |
ACS Biomater Sci Eng
May 2024
Department of Chemical Engineering, Virginia Tech, Blacksburg, Virginia 24060, United States.
Polycationic polymers are widely studied antiseptics, and their efficacy is usually quantified by the solution concentration required to kill a fraction of a population of cells (e.g., by Minimum Bactericidal Concentration (MBC)).
View Article and Find Full Text PDFBiologicals
January 2019
Biopharmaceutical Research Center, AryoGen Pharmed Inc., Alborz University of Medical Sciences, Karaj, Iran.
The cationic polyelectrolyte pDADMAC is widely used in biopharmaceutical industry as a flocculating agent to enhance clarification throughput and downstream filtration operations. Due to the possible toxicity, pDADMAC should be assessed for an acceptable residual level to ascertain the safety of the product to patients. The strong protein-polyelectrolyte interaction, however, can negatively affect sensitivity and accuracy of measurements.
View Article and Find Full Text PDFMAbs
November 2015
a Purification Process Development ; Amgen Inc. ; Seattle , WA USA.
High titer (>10 g/L) monoclonal antibody (mAb) cell culture processes are typically achieved by maintaining high viable cell densities over longer culture durations. A corresponding increase in the solids and sub-micron cellular debris particle levels are also observed. This higher burden of solids (≥15%) and sub-micron particles typically exceeds the capabilities of a continuous centrifuge to effectively remove the solids without a substantial loss of product and/or the capacity of the harvest filtration train (depth filter followed by membrane filter) used to clarify the centrate.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!