Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Weak evidence is present for choosing amongst different temporary hemodialysis catheter (THC) designs with regards to the risk of venous thrombosis, therefore two THC designs for the right internal jugular vein (RIJV) were compared. Patients aged ≥18 years who needed THC insertion into the RIJV for acute hemodialysis due to either acute or chronic renal failure were included. The type of THC (precurved/straight) was dependent on the date of hospital admission. Clinical and ultrasonographic surveillance was conducted prospectively. Thrombosis of the RIJV was the primary objective. Precurved and straight catheters were inserted into 32 and 23 patients (mean age 63 ± 15 years, females 28), respectively. The baseline characteristics and catheter dwell-times were similar in both groups. Partial and total thrombosis of the RIJV during catheter dwell-time developed at a higher rate in the straight group (52% vs. 9.3%, P = 0.000; 47.8% vs. 9.3%, P = 0.001, respectively). At least 2 weeks after catheter removal, total thrombosis was found in 43.4% vs. 9.6% (P = 0.004) of patients with straight and precurved THCs, respectively. The hazard ratios for total thrombosis was 0.161 (P = 0.006) during catheter dwell-time and 0.190 (P = 0.012) after catheter removal. Catheter dysfunction did not occur and only one catheter-related bloodstream infection (CRBI) was seen. Thrombosis rates of the RIJV were higher with straight vs. precurved THCs, both during catheter dwell-time and after catheter removal. Catheter dysfunction was not noted in any group and the rate of CRBI was extremely low.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/1744-9987.12776 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!