Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: To compare mechanisms of and pressures at failure of 4 methods of securing 2 types of cellophane bands around a vein.
Study Design: Ex vivo mechanical evaluation.
Methods: Cellophane bands composed of 3 or 4 layers were applied around a cadaveric external jugular vein (EJV) to create 25% or 50% attenuation. These bands were secured with a medium or medium-large polymer locking ligation clip (PLLC), or a medium or medium-large titanium ligation clip (TLC). Sterile saline 0.9% was instilled into the lumen of the EJV until a pressure of 100 mm Hg was reached. Failure mechanism and luminal pressure at failure were compared between groups.
Results: Medium clips failed less often than medium-large clips (P < .001) and consistently sustained 100 mm Hg without failing. Three-layer cellophane bands were 4.1 times more likely to fail than 4-layer bands (P = .003, CI 1.6-10.2) and failed at lower pressures (28.32 ± 3.59 mm Hg and 44.81 ± 6.51 mm Hg, respectively, P = .027). Failure rates of the cellophane band constructs did not differ whether secured with PLLC or with TLC (P = .635) or with 25% vs 50% attenuation (P = .780).
Conclusion: A single medium clip withstood physiological forces and secured a cellophane band at up to 50% attenuation. A 3-layer cellophane band was more likely to fail compared with a 4-layer cellophane band.
Clinical Significance: These ex vivo results provide evidence to support the application of a 4-layer cellophane band secured with a single medium PLLC or TLC for portosystemic shunt attenuation. A single medium PLLC should be used to eliminate computed tomography artifacts during postoperative evaluation of shunt closure.