A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Formation of by-products during chemical interesterification of lipids. Detection and characterization of dialkyl ketones by non-aqueous reversed-phase liquid chromatography-high resolution mass spectrometry and gas chromatography-mass spectrometry. | LitMetric

A new class of foreign substances present in the unsaponifiable fraction of vegetable oils undergone to chemical interesterification was systematically investigated. Their chemical structure, corresponding to dialkyl ketones (DAK) molecules, was elucidated both by gas chromatography-mass spectrometry (GC-MS), and liquid chromatography-high resolution mass spectrometry (LC-HRMS). An analytical protocol aimed to qualitative and quantitative detection of DAK molecules in vegetable oils of confectionery industry interest was developed. Being the range of concentration levels to be evaluated dependent on the technological task of interesterification process, the quantitation step was thoroughly examined. All the validation parameters were satisfactory and particularly the concentration determinations were made more reliable by the contemporary use of several quantitation standards. GC-MS and LC-HRMS analytical techniques exhibited comparable performances even if the second one shown better detection sensitivity.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2018.11.001DOI Listing

Publication Analysis

Top Keywords

chemical interesterification
8
dialkyl ketones
8
liquid chromatography-high
8
chromatography-high resolution
8
resolution mass
8
mass spectrometry
8
gas chromatography-mass
8
chromatography-mass spectrometry
8
vegetable oils
8
dak molecules
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!