Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background And Purpose: To evaluate the effect of changes in bladder volume during high-dose intensity-modulated-radiotherapy (IMRT) of prostate cancer on acute genitourinary (GU) toxicity and prospectively evaluate a simple biofeedback technique for reproducible bladder filling with the aim of reducing acute GU toxicity.
Methods: One hundred ninety-three patients were trained via a biofeedback mechanism to maintain a partially filled bladder with a reproducible volume of 200-300 cc at planning CT and subsequently at each fraction of radiotherapy. We prospectively analyzed whether and to what extent the patients' ability to maintain a certain bladder filling influenced the degree of acute GU toxicity and whether cut-off values could be differentiated.
Results: We demonstrated that the ability to reach a reproducible bladder volume above a threshold volume of 180 cc and maintain that volume via biofeedback throughout treatment predicts for a decrease in acute GU toxicity during curative high-dose IMRT of the prostate. Patients who were not able to reach a partial bladder filling to that cut-off value and were not able to maintain a partially filled bladder throughout treatment had a significantly higher risk of developing ≥grade 2 GU acute toxicity.
Conclusion: Our results support the hypothesis that a biofeedback training for the patient is an easy-to-apply, useful, and cost-effective tool for reducing acute GU toxicity in high-dose IMRT of the prostate. Patients who are not able to reach and maintain a certain bladder volume during planning and treatment-two independent risk factors-might need special consideration.