This article is a collection of intraoperative techniques performed by a single hand surgeon with literature support for these techniques for the purpose of circumventing potential limitations intraoperatively. These techniques include the use of a Beaver Blade handle (Beaver, Beaver-Visitec, Waltham, MA, US) to be used as a rasp to smooth intraosseous tunnels during tendon transfers, a Stryker (Stryker, Stryker Corporation, Kalamazoo, MI, US) or Synthes (Deputy Synthes, Johnson & Johnson, West Palm Beach, FL, US) drill as a motorized file for plate deburring, and Insorb forceps (Insorb, Incisive Surgical, Plymouth, MN, US) for skin closure. These tips serve as methods to minimize scarring and circumvent unfortunate obstacles, such as tendon rupture, and the consequential weakened repair that can occur post-operatively. These have not been previously reported in the literature but have been performed by the senior author with no resulting complications. Additionally, the common availability of the equipment allows for a potential economic benefit.