NNWarp is a highly re-usable and efficient neural network (NN) based nonlinear deformable simulation framework. Unlike other machine learning applications such as image recognition, where different inputs have a uniform and consistent format (e.g., an array of all the pixels in an image), the input for deformable simulation is quite variable, high-dimensional, and parametrization-unfriendly. Consequently, even though the neural network is known for its rich expressivity of nonlinear functions, directly using an NN to reconstruct the force-displacement relation for general deformable simulation is nearly impossible. NNWarp obviates this difficulty by partially restoring the force-displacement relation via warping the nodal displacement simulated using a simplistic constitutive model-the linear elasticity. In other words, NNWarp yields an incremental displacement fix per mesh node based on a simplified (therefore incorrect) simulation result other than synthesizing the unknown displacement directly. We introduce a compact yet effective feature vector including geodesic, potential and digression to sort training pairs of per-node linear and nonlinear displacement. NNWarp is robust under different model shapes and tessellations. With the assistance of deformation substructuring, one NN training is able to handle a wide range of 3D models of various geometries. Thanks to the linear elasticity and its constant system matrix, the underlying simulator only needs to perform one pre-factorized matrix solve at each time step, which allows NNWarp to simulate large models in real time.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TVCG.2018.2881451DOI Listing

Publication Analysis

Top Keywords

deformable simulation
12
neural network
8
force-displacement relation
8
linear elasticity
8
nnwarp
6
nnwarp neural
4
neural network-based
4
nonlinear
4
network-based nonlinear
4
nonlinear deformation
4

Similar Publications

Exploration of the dynamics of otic capsule and intracochlear pressure: Numerical insights with experimental validation.

J Acoust Soc Am

January 2025

Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Zurich, University of Zurich, Zurich, Switzerland.

The otic capsule and surrounding temporal bone exhibit complex 3D motion influenced by frequency and location of the bone conduction stimulus. The resultant correlation with the intracochlear pressure is not sufficiently understood, thus is the focus of this study, both experimentally and numerically. Experiments were conducted on six temporal bones from three cadaver heads, with BC hearing aid stimulation applied at the mastoid and classical BAHA locations across 0.

View Article and Find Full Text PDF

Programmable scanning diffuse speckle contrast imaging of cerebral blood flow.

Neurophotonics

January 2025

University of Kentucky, Department of Biomedical Engineering, Lexington, Kentucky, United States.

Significance: Cerebral blood flow (CBF) imaging is crucial for diagnosing cerebrovascular diseases. However, existing large neuroimaging techniques with high cost, low sampling rate, and poor mobility make them unsuitable for continuous and longitudinal CBF monitoring at the bedside.

Aim: We aimed to develop a low-cost, portable, programmable scanning diffuse speckle contrast imaging (PS-DSCI) technology for fast, high-density, and depth-sensitive imaging of CBF in rodents.

View Article and Find Full Text PDF

: Asymptomatic patellar tendon abnormality (APTA) is considered a precursor to patellar tendinopathy (PT), but its pathogenesis remains unclear, especially regarding changes in muscle coordination. Therefore, it is essential to explore the muscle synergy patterns in individuals with APTA. This study recorded sEMG data during stop-jump tasks in 8 APTA and 8 healthy amateur male basketball players in a simulated basketball game.

View Article and Find Full Text PDF

Efficacy of SAVE: A Novel Maxillary Protraction Device-A Finite Element Analysis.

Int J Clin Pediatr Dent

December 2024

Department of Orthodontics, Yenepoya Dental College, Yenepoya (Deemed to be University), Mangaluru, Karnataka, India.

Introduction: This study describes a novel device known as "SAVE" to effectively protract the deficient maxilla in class III malocclusion by quantifying and evaluating the changes in the maxilla through a finite element analysis (FEA).

Materials And Methods: The patented novel SAVE device was three-dimensionally modeled using Autodesk Fusion 360. An existing computed tomography (CT) scan of a patient exhibiting class III malocclusion was used to generate a finite element (FE) model.

View Article and Find Full Text PDF

Multiple sclerosis (MS) affects 2.8 million people worldwide. Although the cause is unknown, various risk factors might be involved.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!