Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: Speed-of-sound (SoS) has large potential for tissue and pathology differentiation. We aim to develop a novel Ultrasound Computed Tomography (USCT) technique that can reconstruct local SoS in tissue on conventional ultrasound machines with hand-held linear arrays.
Methods: A passive reflector is placed opposite the tissue sample as an echogenic reference to measure the time-of-flight (ToF) of ultrasound wave- fronts. A Dynamic Programming algorithm provides a robust ToF measurements based on global optimization of all transmit- receive echo data. An Anisotropically-Weighted Total Variation (AWTV) algorithm allows sharp delineation of focal lesions based on limited-angle USCT data.
Results: Inclusions, which are not visible in conventional ultrasound, could be delineated in SoS images. AWTV allows to reconstruct focal lesions with a contrast-ratio of 93.7% of their nominal value, compared to that of 31.5% with conventional least-squares based algebraic tomographic reconstruction. In full-wave simulations of realistic heterogeneous breast models, a high CR of 84.3% is observed, with the reconstruction filtering out background heterogeneity. In experiments, our proposed method quantifies SoS in a homogeneous background with an accuracy of 0.93ms, allowing to differentiate several tissue types.
Conclusion: We validate our method using numerical simulations with ray-tracing and full- wave models, and phantom and ex-vivo data. Preliminary in- vivo results show the potential of this new technique to detect and differentiate malignant and benign lesions in the breast.
Significance: Breast cancer is the most common cancer in women. Ultrasound B-mode only provides qualitative information about breast lesions, whereas USCT can provide quantitative tissue imaging biomarkers, such as SoS. The proposed method can potentially be implemented as a complementary modality to ultrasound for tissue and disease differentiation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/TBME.2018.2881302 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!