Background: Anaesthetic medication administration errors are a significant threat to patient safety. In 2002, we began collecting data about the rate and nature of anaesthetic medication errors and implemented a variety of measures to reduce errors.

Methods: Facilitated self-reporting of errors was carried out in 2002-2003. Subsequently, a medication safety bundle including 'smart' infusion pumps were implemented. During 2014 facilitated self-reporting commenced again. A barcode-based medication safety system was then implemented and the facilitated self-reporting was continued through 2015.

Results: During 2002-2003, a total of 11 709 paper forms were returned. There were 73 reports of errors (0.62% of anaesthetics) and 27 reports of intercepted errors (0.23%). During 2014, 14 572 computerised forms were completed. There were 57 reports of errors (0.39%) and 11 reports of intercepted errors (0.075%). Errors associated with medication infusions were reduced in comparison with those recorded in 2002-2003 (P<0.001). The rate of syringe swap error was also reduced (P=0.001). The reduction in error rate between 2002-2003 and 2014 was statistically significant (P=0.0076 and P=0.001 for errors and intercepted errors, respectively). From December 2014 through December 2015, 24 264 computerised forms were completed after implementation of a barcode-based medication safety system. There were 56 reports of errors (0.23%) and six reports of intercepted errors (0.025%). Vial swap errors in 2014-2015 were significantly reduced compared with those in 2014 (P=0.004). The reduction in error rate after implementation of the barcode-based medication safety system was statistically significant (P=0.0045 and P=0.021 for errors and intercepted errors, respectively).

Conclusions: Reforms intended to reduce medication errors were associated with substantial improvement.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bja.2018.09.004DOI Listing

Publication Analysis

Top Keywords

anaesthetic medication
12
facilitated self-reporting
12
errors
9
medication errors
8
safety bundle
8
safety system
8
medication safety
8
reports errors
8
reports intercepted
8
intercepted errors
8

Similar Publications

Background: Disparities in labor epidural analgesia (LEA) management could reduce maternal satisfaction and increase risk. We compared times from the first administration of breakthrough pain medication (top-up) to LEA replacement to evaluate disparities across race.

Methods: In this retrospective cohort study (01-01-2018 to 12-31-2022), all patients with LEA and maternal race/ethnicity of non-Hispanic White or Black were eligible.

View Article and Find Full Text PDF

» Increased professional, personal, and emotional stress can have compounding negative effects on physicians, which can be detrimental to teamwork dynamics, workplace environment, productivity, and personal well-being. Orthopaedic surgery, in particular, is a medical specialty that demonstrates high workplace demands, elevated rates of burnout, and low workplace diversity.» Professional coaching can help combat these challenges and facilitate professional success by providing an outlet for discussion and planning toward one's career development and goals.

View Article and Find Full Text PDF

Background: Iliopsoas injuries are a common cause of anterior hip and groin pain and can be successfully managed with conservative treatment. Corticosteroid and local anesthetic injections can also be offered in conjunction with nonoperative management. Given the variability in reported injection guidelines, composition, and techniques, the purpose of this study was to systematically review the literature to assess progression to surgery and patient outcomes following iliopsoas injections.

View Article and Find Full Text PDF

Precise and rapid disease detection is critical for controlling infectious diseases like COVID-19. Current technologies struggle to simultaneously identify viral RNAs and host immune antibodies due to limited integration of sample preparation and detection. Here, we present acoustofluidic integrated molecular diagnostics (AIMDx) on a chip, a platform enabling high-speed, sensitive detection of viral immunoglobulins [immunoglobulin A (IgA), IgG, and IgM] and nucleic acids.

View Article and Find Full Text PDF

Alzheimer's disease (AD) is the most prevalent neurodegenerative disorder. Antiamyloid antibody treatments modestly slow disease progression in mild dementia due to AD. Emerging evidence shows that homeostatic dysregulation of the brain immune system, especially that orchestrated by microglia, plays an important role in disease onset and progression.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!