A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Performance of Combined Surface and Intramuscular EMG for Classification of Hand Movements. | LitMetric

The surface EMG (sEMG) has been used as control source for upper limb prosthetics since decades. Previous studies suggested that intramuscular EMG showed promising results for upper limb prosthetics. This study investigates the strength of combined surface and intramuscular EMG (cEMG) for improved myoelectric control. Five able-bodied subjects and three transradial amputees were evaluated using offline classification error as performance metric. Six surface and intramuscular channels were recorded concurrently from each subject for seven consecutive days and Stacked sparse autoencoders (SSAE) and LDA classifiers were used for classification. As a control source, either sEMG channels were used or combined channels were used with reduced features using PCA. In the within session analysis, cEMG $( 2.21 \pm 1.19${%) outperformed the sEMG ($4.63 \pm 2.07${%) for both able-bodied and amputee subjects using SSAE. For between session analysis, cEMG outperformed the sEMG for both able-bodied and amputee subjects with percentage points difference of 7.93. These results imply cEMG can significantly improve the performance of pattern recognition based myoelectric control scheme for amputee subjects too and further improvement can be made by utilizing SSAE which show improved performance as compared to LDA.

Download full-text PDF

Source
http://dx.doi.org/10.1109/EMBC.2018.8513480DOI Listing

Publication Analysis

Top Keywords

surface intramuscular
12
intramuscular emg
12
amputee subjects
12
combined surface
8
control source
8
upper limb
8
limb prosthetics
8
myoelectric control
8
session analysis
8
analysis cemg
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!