A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Modeling of Hand and Forearm Link using Inertial Sensors. | LitMetric

In this paper, we describe our hand and forearm motion measuring system using inertial sensors. Although a sensor axis is often used to measure human body motion, it is prone to attachment and offset error, and, because a hand is made of five parallel links, it is not suitable for hand measurement. Therefore, we propose a method of modeling the hand and forearm link using only sensors. To model a finger link, a compass' azimuth deviation is important because it may affect the intersection of the fingers. Therefore, before modeling, we applied correction and alternative methods using the angular velocity direction. As a result, the deviation between the sensors decreased to 1/5. During the modeling, we estimated the sensor's position vectors on the distal and next distal segments from each joint, and calculated the relationship matrices between the sensors through initial posture during estimation. We created the hand and forearm link model by combining the position vectors and relationship matrices. Comparison with optical motion capture showed that the hand shape without intersection of the fingers matched well, but there was offset because the forearm sensors deviated from the estimated positions. Although we must improve the attachment to the forearm, these methods proved effective for hand motion measurement.

Download full-text PDF

Source
http://dx.doi.org/10.1109/EMBC.2018.8513404DOI Listing

Publication Analysis

Top Keywords

hand forearm
16
forearm link
12
modeling hand
8
inertial sensors
8
intersection fingers
8
position vectors
8
relationship matrices
8
hand
7
forearm
6
sensors
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!