The number of implantable bidirectional neural interfaces available for neuroscientific research applications is still limited, despite the rapidly increasing number of customized components. We previously reported on how to translate available components into "ready-to-use" wireless implantable systems utilizing components off-the-shelf (COTS). The aim of the present study was to verify the viability of a micro-electrocorticographic ($\mu $ECoG) device built by this approach. Functionality for both neural recording and stimulation was evaluated in an ovine animal model using acoustic stimuli and cortical electrical stimulation, respectively. We show that auditory evoked responses were reliably recorded in both time and frequency domain and present data that demonstrates the cortical electrical stimulation functionality. The successful recording of neuronal activity suggests that the device can compete with existing implantable systems as a neurotechnological research tool.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/EMBC.2018.8513044 | DOI Listing |
Spine Deform
January 2025
Department of Spine Surgery, Eifelklinik St Brigida, St. Brigida Eifelklinik, Kammerbruchst. 8, 52152, Simmerath, Germany.
Purpose: To evaluate the sites where the tether breaks in vertebral body tethering (VBT) cases.
Methods: Intraoperative evaluation of broken tethers in patients who had anterior revision.
Inclusion Criteria: anterior revision of VBT cases with explantation of the full implant and photo documentation.
Oper Orthop Traumatol
January 2025
Klinik für Unfall‑, Hand und Wiederherstellungschirurgie, Universitätsmedizin Rostock, Schillingallee 35, 18057, Rostock, Deutschland.
Objective: Treatment with transcutaneous osseointegrated prosthesis systems (TOPS) for short femoral amputation stumps aims to restore independent walking ability after proximal femoral amputation by direct bone-guided prosthesis anchorage. This cannot be safely achieved with conventional socket prostheses due to the mechanically inadequate socket contact surface.
Indications: Treatment of patients with short transfemoral stumps who cannot be mobilized sufficiently with conventional socket prostheses.
BMJ Case Rep
January 2025
Cardiology, AIIMS, New Delhi, India
A young man in his 30s presented to us with multiple episodes of syncope and exertional dyspnoea for the last 2 weeks. He was diagnosed with squamous cell carcinoma of the lower one-third of the oesophagus in 2021 for which he was treated with neoadjuvant chemoradiotherapy, followed by McKeown oesophagectomy. At 2-year follow-up, he had developed a soft tissue swelling in the scalp, which was diagnosed as a tumour recurrence and radiotherapy was initiated.
View Article and Find Full Text PDFJ Neural Eng
January 2025
Department of Neurology Neuroscience, University of Amsterdam, Meibergdreef 9, Amsterdam, 1105AZ, NETHERLANDS.
Local field potential (LFP) recordings using chronically implanted sensing-enabled stimulators are a powerful tool for indexing symptom presence and severity in neurological and neuropsychiatric disorders, and for enhancing our neurophysiological understanding of brain processes. LFPs have gained interest as input signals for closed-loop deep brain stimulation (DBS) and can be used to inform DBS parameter selection. LFP recordings using chronically implanted sensing-enabled stimulators have various implementational challenges.
View Article and Find Full Text PDFACS Appl Mater Interfaces
January 2025
DWI─Leibniz Institute for Interactive Materials e.V., Forckenbeckstraße 50, Aachen 52074, Germany.
The global dental implant market is projected to reach $9.5 billion by 2032, growing at a 6.5% compound annual growth rate due to the rising prevalence of dental diseases.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!