Sleep monitoring provides valuable insights into the general health of an individual and helps in the diagnostic of sleep-derived illnesses. Polysomnography, is considered the gold standard for such task. However, it is very unwieldy and therefore not suitable for long-term analysis. Here, we present a non-intrusive wearable system that, by using photoplethysmography, it can estimate beat-to-beat intervals, pulse rate, and breathing rate reliably during the night. The performance of the proposed approach was evaluated empirically in the Department of Psychology at the University of Fribourg. Each participant was wearing two smart-bracelets from Ava as well as a complete polysomnographic setup as reference. The resulting mean absolute errors are 17.4ms (MAPE 1.8%) for the beat-to-beat intervals, 0.13beats-per-minute (MAPE 0.20%) for the pulse rate, and 0.9breaths-per-minute (MAPE 6.7%) for the breath rate.

Download full-text PDF

Source
http://dx.doi.org/10.1109/EMBC.2018.8512881DOI Listing

Publication Analysis

Top Keywords

beat-to-beat intervals
8
pulse rate
8
respiratory cardiac
4
cardiac monitoring
4
monitoring night
4
night wrist
4
wrist wearable
4
wearable optical
4
optical system
4
system sleep
4

Similar Publications

Background: Individuals with spinal cord injury (SCI) commonly have autonomic dysreflexia (AD) with increased sympathetic activity. After SCI, individuals have decreased baroreflex sensitivity and increased vascular responsiveness.

Objective: To evaluate the relationship between baroreflex and blood vessel sensitivity with AD symptoms.

View Article and Find Full Text PDF

We developed a deep learning-based extraction of electrocardiographic (ECG) waves from ballistocardiographic (BCG) signals and explored their use in R-R interval (RRI) estimation. Preprocessed BCG and reference ECG signals were inputted into the bidirectional long short-term memory network to train the model to minimize the loss function of the mean squared error between the predicted ECG (pECG) and genuine ECG signals. Using a dataset acquired with polyvinylidene fluoride and ECG sensors in different recumbent positions from 18 participants, we generated pECG signals from preprocessed BCG signals using the learned model and evaluated the RRI estimation performance by comparing the predicted RRI with the reference RRI obtained from the ECG signal using a leave-one-subject-out cross-validation scheme.

View Article and Find Full Text PDF

Assessment of cerebral oxygenation during repeated squat stands following an acute sport-related concussion (SRC) has the potential to identify physiological changes following SRC. All varsity university athletes completed a pre-season assessment and 53 were followed up within 5-days of suffering an SRC. Of the 53 participants, 29 had continuous beat-to-beat blood pressure (BP; sampled at 200 hz) collected by finger photoplethysmography, and 53 had right prefrontal cortex oxygenation collected by near-infrared spectroscopy (NIRS; sampled at 10 hz).

View Article and Find Full Text PDF

Baroreflex Sensitivity and Long-Term Dementia Risk in Older Adults.

Hypertension

February 2025

Department of Epidemiology (M.K., A.H., F.J.W., M.A.I.), Erasmus MC University Medical Center, Rotterdam, The Netherlands.

Background: Increased blood pressure (BP) variability is linked to dementia risk, but the relationship between baroreflex sensitivity (BRS), a fundamental mechanism for maintaining stable BP, and dementia risk is undetermined.

Methods: We tested the hypothesis that impaired BRS is associated with increased dementia risk in 1819 older adults (63% women; age, 71.0±6.

View Article and Find Full Text PDF

Introduction: Fetal scalp electrode (FSE) is considered the gold standard for the intrapartum monitoring of the fetal heart rate (FHR) being associated with the lowest rate of signal loss and artifacts including the recording of the maternal heart rate. FSE acquires a fetal electrocardiogram and evaluates the time intervals between successive R waves. As such, it allows the recording of the beat-to-beat fluctuation of the FHR.

View Article and Find Full Text PDF