A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Unobtrusive Heartbeat Detection from Mice Using Sensors Embedded in the Nest. | LitMetric

Unobtrusive monitoring of physio-behavioral variables from animals can minimize variability in preclinical research and thereby maximize the potential for clinical translation. In this paper, we present the design, implementation, and validation of an instrumented nest providing continuous recordings of seismocardiogram (SCG) signals and skin temperature. SCG represents the chest-wall vibrations associated with the heartbeat, and can potentially provide a measure by which individual heartbeats can be detected without the need for electrodes or implantable devices. A non-contact electric field sensor placed in proximity to the animal in the nest was also used to detect respiratory dynamics. The setup was tested with a total of six anesthetized mice. To understand the effects of mouse positioning within the nest on signal quality, the error in heartbeat detection at different positions of the sensor on the body was quantified, with a simultaneously-obtained electrocardiogram (ECG) as the reference standard. At the optimal placement determined with this approach, multiple perturbations were performed such as pinching, changing ambient temperature, and norepinephrine injection to modulate physiology and assess measurement capability. Heartbeat intervals obtained from the ECG and SCG during the perturbations were correlated (R=0.82) and were in agreement according to Bland-Altman methods (bias: 0.006ms, 95% confidence interval: [-3.79, 3.78]ms) suggesting that SCG can be reliably used for unobtrusive heartbeat detection. Accordingly, the setup can provide a means by which individual heartbeats - and thereby heart rate and heart rate variability indices - can be quantified without the need for any sensors to be attached to the body of the animal.

Download full-text PDF

Source
http://dx.doi.org/10.1109/EMBC.2018.8512611DOI Listing

Publication Analysis

Top Keywords

heartbeat detection
12
unobtrusive heartbeat
8
individual heartbeats
8
heart rate
8
detection mice
4
mice sensors
4
sensors embedded
4
nest
4
embedded nest
4
nest unobtrusive
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!