Objective:: To assess the accuracy and efficiency of four different techniques, thus determining the optimum method for recalculating dose on cone beam CT (CBCT) images acquired during radiotherapy treatments.

Methods:: Four established techniques were investigated and their accuracy assessed via dose calculations: (1) applying a standard planning CT (pCT) calibration curve, (2) applying a CBCT site-specific calibration curve, (3) performing a density override and (4) using deformable registration. Each technique was applied to 15 patients receiving volumetric modulated arc therapy to one of three treatment sites, head and neck, lung and prostate. Differences between pCT and CBCT recalculations were determined with dose volume histogram metrics and 2.0%/0.1 mm gamma analysis using the pCT dose distribution as a reference.

Results:: Dose volume histogram analysis indicated that all techniques yielded differences from expected results between 0.0 and 2.3% for both target volumes and organs at risk. With volumetric gamma analysis, the dose recalculation on deformed images yielded the highest pass-rates. The median pass-rate ranges at 50% threshold were 99.6-99.9%, 94.6-96.0%, and 94.8.0-96.0% for prostate, head and neck and lung patients, respectively.

Conclusion:: Deformable registration, HU override and site-specific calibration curves were all identified as dosimetrically accurate and efficient methods for dose calculation on CBCT images.

Advances In Knowledge:: With the increasing adoption of CBCT, this study provides clinical radiotherapy departments with invaluable information regarding the comparison of dose reconstruction methods, enabling a more accurate representation of a patient's treatment. It can also integrate studies in which CBCT is used in image-guided radiation therapy and for adaptive radiotherapy planning processes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6540850PMC
http://dx.doi.org/10.1259/bjr.20180383DOI Listing

Publication Analysis

Top Keywords

dose
9
dose calculation
8
cone beam
8
calibration curve
8
site-specific calibration
8
deformable registration
8
head neck
8
neck lung
8
dose volume
8
volume histogram
8

Similar Publications

Feasibility of very low iodine dose aortoiliac CT angiography using dual-source photon-counting detector CT.

Eur J Radiol

January 2025

Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany; Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, USA. Electronic address:

Purpose: To evaluate the feasibility of aortoiliac CT-Angiography (CTA) using dual-source photon-counting detector (PCD)-CT with minimal iodine dose.

Methods: This IRB-approved, single-center prospective study enrolled patients with indications for aortoiliac CTA from December 2022 to March 2023. All scans were performed using a first-generation dual-source PCD-CT.

View Article and Find Full Text PDF

Background: In Catalonia, infants <6 months old were eligible to receive nirsevimab, a novel monoclonal antibody against respiratory syncytial virus (RSV). We aimed to analyze nirsevimab's effectiveness in hospital-related outcomes of the seasonal cohort (born during the RSV epidemic from October to January 2024) and compared them with the catch-up cohort (born from April to September 2023).

Methods: Retrospective cohort study of all infants born between October 1, 2023, and January 21, 2024, according to their immunization with nirsevimab (immunized and nonimmunized).

View Article and Find Full Text PDF

Vision loss affects more than 7 million Americans and impacts quality of life, independence, social functioning, and overall health. Common and dangerous conditions causing sudden vision loss include acute angle-closure glaucoma, retinal detachment, retinal artery occlusion, giant cell arteritis, and optic neuritis. Acute angle-closure glaucoma features ocular pain, headache, and nausea; treatment includes pilocarpine eye drops, oral or intravenous acetazolamide, and intravenous mannitol.

View Article and Find Full Text PDF

Objective: Ventricular shunt insertion is a common procedure in pediatric neurosurgical practice. In many areas of medicine there is a push toward rationalization of healthcare resources and a reduction in low-value tests or procedures. The intraoperative sampling of CSF at the time of shunt insertion is one traditional aspect of care that has not been rigorously evaluated.

View Article and Find Full Text PDF

Objective: The purpose of this study was to present a newly designed 3D-printed personalized model (3D PPM) of a radiofrequency needle guide with a maxillary fixation for gasserian ganglion (GG) puncture.

Methods: Implementation of 3D CT-guided radiofrequency therapy of the GG with and without use of 3D PPM was analyzed. The following parameters were assessed: radiation time, dose area product, air kerma reference point, pain severity during the puncture needle insertion, prosopalgia regression degree (according to visual analog scale) and the severity of facial numbness (according to the Barrow Neurological Institute scale) in the early postoperative period, and postpuncture complications.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!