This paper builds on the fact that high aspect ratio rectilinear tubing columns of the same length and outside dimensions can double column efficiency. It demonstrates that further improvements in efficiency can be made by using rectilinear tubing columns with half the wall thickness thus replacing heavy PTFE with light solvent systems and producing lighter higher capacity columns. Increases in sample loading/throughput of up to 55x are demonstrated by comparing the separation of Honokiol and Magnolol using a Hexane: Ethyl Acetate: Methanol: Water (5:2:5:2) phase system with the new thin wall rectilinear column (56 mL, 30 mL/min, 2.1 g/h in 6.5 min.) with the original optimization performed using a conventional DE-Mini column (18 mL, 0.8 mm bore circular PTFE tubing, 2.5 mL/min, 0.038 g/h in 45 min.). Honokiol is currently going through first phase clinical trials as an anti-lung cancer therapy where preparative countercurrent chromatography was used for its manufacture. To be competitive in the future it is important for the technology to become more efficient. This is the first big step in that direction.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.chroma.2018.10.012 | DOI Listing |
Khirurgiia (Mosk)
April 2024
Kuban State Medical University, Krasnodar, Russia.
ACS Cent Sci
March 2024
Department of Mechanical Engineering, University of California at Santa Barbara, Santa Barbara, California 93106-5070, United States.
Fast and programmable transport of droplets on a substrate is desirable in microfluidic, thermal, biomedical, and energy devices. Photoresponsive surfactants are promising candidates to manipulate droplet motion due to their ability to modify interfacial tension and generate "photo-Marangoni" flow under light stimuli. Previous works have demonstrated photo-Marangoni droplet migration in liquid media; however, migration on other substrates, including solid and liquid-infused surfaces (LIS), remains an outstanding challenge.
View Article and Find Full Text PDFJ Colloid Interface Sci
June 2022
State Key Laboratory of Coordination Chemistry, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, China. Electronic address:
Hypothesis: Formation of coupled double crossovers (DXs) in a circular 106-mer oligonucleotide (c106nt) could generate stable tiles with the tile core span of 10 half turns. The large-span tiles with complicated curvatures and mechanics could assemble 2D lattices under different environments. Hence, 2D DNA lattice structures based on tile types and sequences, tile packing modes of corrugation and non-corrugation, and assembly media of solution and the substrate-solution interface are yet to be explored.
View Article and Find Full Text PDFJ Chromatogr A
December 2018
Advanced Bioprocessing Centre, Institute of Environment, Health and Societies, Brunel University London, Uxbridge, Middlesex, UB8 3PH, UK.
Increasing column/tubing aspect ratio has been shown in a feasibility study to improve column efficiency when operating in reversed phase mode. This paper contains a thorough investigation on how increases in mobile phase flow and centrifugal force field affect stationary phase retention and column efficiency (as measured by the resolution between adjacent peaks) for columns wound with rectilinear tubing of different aspect ratio. The study uses a Mini CCC instrument operating from 1500 to 2100 rpm (126-246 g) to compare three columns with the same cross-sectional area but different aspect ratio - rectangular horizontal (force field perpendicular to the flat side - aspect ratio 3.
View Article and Find Full Text PDFJ Chromatogr A
December 2018
Advanced Bioprocessing Centre, Institute of Environment, Health and Societies, Brunel University London, Uxbridge, Middlesex, UB8 3PH, UK; Department of Chemical Engineering, College of Engineering, Design and Physical Sciences, Brunel University London, UB8 3PH, UK.
This paper builds on the fact that high aspect ratio rectilinear tubing columns of the same length and outside dimensions can double column efficiency. It demonstrates that further improvements in efficiency can be made by using rectilinear tubing columns with half the wall thickness thus replacing heavy PTFE with light solvent systems and producing lighter higher capacity columns. Increases in sample loading/throughput of up to 55x are demonstrated by comparing the separation of Honokiol and Magnolol using a Hexane: Ethyl Acetate: Methanol: Water (5:2:5:2) phase system with the new thin wall rectilinear column (56 mL, 30 mL/min, 2.