Purpose: This within-subject comparison tested the null hypothesis that there is no difference in patient satisfaction and oral health-related quality of life when an individual with an edentulous mandible is rehabilitated with a two-implant overdenture or a three-implant-supported fixed dental prosthesis.

Materials And Methods: Twelve subjects with an edentulous mandible or failing dentition were rehabilitated with the use of endosseous dental implants. Three implants were placed, and were immediately loaded with a provisional fixed prosthesis with minimal cantilever. After healing for 4 months, two Locator attachments were inserted and an overdenture was trialed; then, after a further 4 months, a fixed prosthesis was placed on the three implants. The fixed prosthesis was fabricated using computer-assisted design, and a titanium framework was manufactured with a resin base and teeth. Patient satisfaction and oral health-related quality of life was assessed before treatment, after wearing the provisional, and after each treatment option using a seven-item visual analog scale and a modified version of the 49-item oral health impact profile.

Results: Of the 12 subjects, 11 chose the fixed over the removable prosthesis. A statistically significant (P < .05) and positive effect on the overall score of both assessment tools was reported for both treatment modalities (when compared with pretreatment scores). Although no significant difference (P > .05) was found between the two options in overall scores of both surveys or in any of the seven domains of the modified oral health impact profile, the fixed prosthesis had a statistically higher score for stability, retention, and ease of chewing on a visual analog scale.

Conclusion: Both treatment modalities provided a significant and similar improvement in patient satisfaction and oral health-related quality of life compared with a conventional complete mandibular removable dental prosthesis; however, a statistically significant higher score was reported for stability, retention, and ease of chewing for the fixed dental prostheses. Based on the 12 participants in this study, greater stability and ease of chewing with the fixed prosthesis likely influenced patient preference in most but not all subjects.

Download full-text PDF

Source
http://dx.doi.org/10.11607/jomi.6666DOI Listing

Publication Analysis

Top Keywords

fixed prosthesis
20
patient satisfaction
16
quality life
16
fixed dental
12
satisfaction oral
12
oral health-related
12
health-related quality
12
prosthesis statistically
12
ease chewing
12
fixed
9

Similar Publications

Design: A triple-armed, double-blind randomized controlled trial with cross-over design investigated patient-reported satisfaction and objective dental evaluation of a 3-unit, monolithic zirconium dioxide (ZrO2), implant-supported fixed dental prosthesis (iFDP) fabricated with 2 completely digital workflows and 1 mixed analog-digital workflow.

Case Selection: Participants enrolled required rehabilitation of 2 dental implants in posterior region of either of the arches with a 3-unit, ZrO2 iFDP. A total of 20 participants received the 3 types of ZrO2, iFDP fabricated by 3 different methods.

View Article and Find Full Text PDF

Design: A retrospective cohort study assessing the mid-to-long-term outcomes and risk factors affecting the prosthetic success and survival of implant-supported cross-arch fixed dental prostheses (IFCDPs) with monolithic zirconia frameworks.

Cohort Selection: Forty-seven patients received a total of 51 cross-arch prostheses (27 maxillary and 24 mandibular prostheses), supported by 302 implants. Comprehensive clinical and radiographic records were available over a follow-up period ranging from 5 to 13 years.

View Article and Find Full Text PDF

Transcatheter aortic valve-in-valve replacement presents a viable, minimally invasive approach to replacing degraded bioprosthetic surgical valves. The major drawback of this technique is poor hemodynamics in the form of patient-prosthesis mismatch and high transvalvular gradients. This is commonly attributable to the reduced valvular diameter from the transcatheter heart valve fixed inside the degraded bioprosthesis.

View Article and Find Full Text PDF

Objective: Aim: Study the mechanism of interaction between the 'sacroiliac joint - screw' system and determine the optimal parameters of the stabilizing structure, the strength of the system connection through computer modeling, and anatomical-biomechanical experiment.

Patients And Methods: Materials and Methods: The optimal parameters of the stabilizing structure for the sacroiliac joint were calculated using software package MathCAD. To validate the results of the numerical modeling, corresponding investigations of mechanical characteristics and determination of stiffness of the studied systems were conducted by an upgraded testing stand, TIRAtest-2151.

View Article and Find Full Text PDF

Objective: The aim of this study was to evaluate whether the locking femoral neck plate (LFNP) can be an alternative fixation method to the cannulated screws with a medial buttress plate. For this purpose, we compared biomechanically the LFNP and cannulated screws with or without a medial buttress plate in Pauwels type 3 femoral neck fractures.

Methods: A vertical fracture model was created at an 80-degree angle to the femoral neck in 28 synthetic bone models.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!