Background: Monitoring footprints during walking can lead to better identification of foot structure and abnormalities. Current techniques for footprint measurements are either static or dynamic, with low resolution. This work presents an approach to monitor the plantar contact area when walking using high-speed videography.

Methods: Footprint images were collected by asking the participants to walk across a custom-built acrylic walkway with a high-resolution digital camera placed directly underneath the walkway. This study proposes an automated footprint identification algorithm (Automatic Identification Algorithm) to measure the footprint throughout the stance phase of walking. This algorithm used coloration of the plantar tissue that was in contact with the acrylic walkway to distinguish the plantar contact area from other regions of the foot that were not in contact.

Results: The intraclass correlation coefficient (ICC) demonstrated strong agreement between the proposed automated approach and the gold standard manual method (ICC = 0.939). Strong agreement between the two methods also was found for each phase of stance (ICC > 0.78).

Conclusions: The proposed automated footprint detection technique identified the plantar contact area during walking with strong agreement with a manual gold standard method. This is the first study to demonstrate the concurrent validity of an automated identification algorithm to measure the plantar contact area during walking.

Download full-text PDF

Source
http://dx.doi.org/10.7547/17-118DOI Listing

Publication Analysis

Top Keywords

plantar contact
20
contact area
20
area walking
16
automated footprint
12
algorithm measure
12
identification algorithm
12
strong agreement
12
concurrent validity
8
validity automated
8
footprint detection
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!