Correction of respiratory and cardiac motion in cardiac PET/MR using MR-based motion modeling.

Phys Med Biol

Translational and Molecular Imaging Institute, Icahn School of Medicine at Mount Sinai, One Gustave Levy Pl, New York, NY 10029, United States of America. Author to whom any correspondence should be addressed.

Published: November 2018

Cardiac positron emission tomography (PET) imaging suffers from image blurring due to the constant motion of the heart that can impact interpretation. Hybrid PET/magnetic resonance (MR) has the potential to use radiation-free MR imaging to correct for the effects of cardio-respiratory motion in the PET data, improving qualitative and quantitative PET imaging in the heart. The purpose of this study was (i) to implement a MR image-based motion-corrected PET/MR method and (ii) to perform a proof-of-concept study of quantitative myocardial PET data in patients. The proposed method takes reconstructions of respiratory and cardiac gated PET data and applies spatial transformations to a single reference frame before averaging to form a single motion-corrected PET (MC-PET) image. Motion vector fields (MVFs) describing the transformations were derived from affine or non-rigid registration of respiratory and cardiac gated MR data. Eight patients with suspected cardiac sarcoidosis underwent cardiac PET/MR imaging after injection of 5 MBq kg of F-fluorodeoxyglucose (F-FDG). Myocardial regions affected by motion were identified by expert readers within which target-to-background ratios (TBR) and contrast-to-noise ratios (CNR) were measured on non-MC-non-gated, MC-PET, and double respiratory and cardiac gated PET images. Paired t-tests were used to determine statistical differences in quantitative uptake-measures between the different types of PET images. MC-PET images showed less blurring compared to non-MC-non-gated PET and tracer activity qualitatively aligned better with the underlying myocardial anatomy when fused with MR. TBR and CNR were significantly greater for MC-PET (2.8  ±  0.9; 21  ±  22) compared to non-MC-non-gated PET (2.4  ±  0.9, p  =  0.0001; 15  ±  13, p  =  0.02), while TBR was lower and CNR greater compared to double-gated PET (3.2  ±  0.9, p  =  0.04; 6  ±  3, p  =  0.004). This study demonstrated in a patient cohort that motion-corrected (MC) cardiac PET/MR is feasible using a retrospective MR image-based method and that improvement in TBR and CNR are achievable. MC PET/MR holds promise for improving interpretation and quantification in cardiac PET imaging.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6425973PMC
http://dx.doi.org/10.1088/1361-6560/aaea97DOI Listing

Publication Analysis

Top Keywords

respiratory cardiac
16
cardiac pet/mr
12
pet
12
pet imaging
12
pet data
12
cardiac gated
12
cardiac
10
data patients
8
gated pet
8
pet images
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!