Pseudo-Continuous Flow FTIR System for Glucose, Fructose and Sucrose Identification in Mid-IR Range.

Micromachines (Basel)

LABioTRON Bioengineering Research Laboratory, ECE Department, Université Laval, Québec City, QC G1V 0A6, Canada.

Published: October 2018

In this paper, we present a new FTIR-based microfluidic system for Glucose, Fructose and Sucrose detection. The proposed microfluidic system is based on a pseudo-continuous flow coupled to a microscope-FTIR instrument. The detection and characterization of sugar samples were performed by recording their absorption spectrum in the wavelength range 700⁻1000 cm - 1 of the Mid-IR region. The proposed pseudo-continuous flow system is designed to improve the uniformity of the sample distribution in the analyzed area versus conventional systems. The obtained results for different sugars concentrations, show a very low measurement error of 4.35% in the absorption peak intensity, which is ten times lower than the error obtained using the conventional measurements.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6215248PMC
http://dx.doi.org/10.3390/mi9100517DOI Listing

Publication Analysis

Top Keywords

pseudo-continuous flow
12
system glucose
8
glucose fructose
8
fructose sucrose
8
microfluidic system
8
flow ftir
4
system
4
ftir system
4
sucrose identification
4
identification mid-ir
4

Similar Publications

Psilocin, the active metabolite of psilocybin, is a psychedelic and agonist at the serotonin 2A receptor (5-HT2AR) that has shown positive therapeutic effects for brain disorders such as depression. To elucidate the brain effects of psilocybin, we directly compared the acute effects of 5-HT2AR agonist (psilocybin) and antagonist (ketanserin) on cerebral blood flow (CBF) using pseudo-continuous arterial spin labeling magnetic resonance imaging (MRI) in a single-blind, cross-over study in 28 healthy participants. We evaluated associations between plasma psilocin level (PPL) or subjective drug intensity (SDI) and CBF.

View Article and Find Full Text PDF

Background: Aβ deposition in the brain does not necessarily lead to cognitive impairment, and that blood supply may have other unexplained regulatory effects on Aβ. Therefore, there appears to be a more complex relationship between blood supply, Aβ deposition, and cognitive impairment that warrants further exploration.

Methods: This cohort study collected four longitudinal follow-up datasets, including a total of 281 subjects, followed for four years.

View Article and Find Full Text PDF

Normal aging has been associated with increased arterial transit time (ATT) and reduced cerebral blood flow (CBF). However, age-related patterns of ATT and CBF and their relationship remain unclear. This is partly due to the lengthy scan times required for ATT measurements, which caused previous age-related CBF studies to not fully account for transit time.

View Article and Find Full Text PDF

Cerebral blood flow alterations measured by ASL-MRI as a predictor of vascular dementia in small vessel ischemic disease.

Radiologia (Engl Ed)

February 2025

Grupo de Espectroscopia e Imágenes Cuantitativas por RM, Centro de Investigación de Imágenes Celulares y Moleculares, Universidad de Ciencias Médicas de Teherán, Teheran, Iran.

Background: Cerebral small vessel ischemic disease (SVID) as a common age-related morbidity is the key mechanism of vascular cognitive impairment (VCI). This study uses Cerebral blood flow (CBF) measured by pseudo-continuous ASL MRI in SVID patients with and without cognitive impairment to differentiate VCI from normal aging.

Materials And Methods: In this cross-sectional study, 74 SVID patients, including 35 with diagnosed VCI and 39 without cognitive impairment (control) underwent pCASL-MRI in the resting state.

View Article and Find Full Text PDF

Background: Perfusion imaging of the brain has important clinical applications in detecting neurological abnormalities in neonates. However, such tools have not been available to date. Although arterial-spin-labeling (ASL) MRI is a powerful noninvasive tool to measure perfusion, its application in neonates has encountered obstacles related to low signal-to-noise ratio (SNR), large-vessel contaminations, and lack of technical development studies.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!