Fabrication of 3D Capillary Vessel Models with Circulatory Connection Ports.

Micromachines (Basel)

Department of Micro-Nano Mechanical Science and Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8601, Japan.

Published: February 2018

Bionic microscopic vessel models can contribute to the development of vascular treatment skills and techniques for clinical training. Most microscopic vessel models are limited to two dimensions, but three-dimensional (3D) models are important for surgery, such as on retina microscopic vessels, for the observation of colon microvessels, for measuring the deformability of red blood cell (RBC), and so on. Therefore, bionic 3D blood vessel models are increasingly in demand. For this reason, it is necessary to establish 3D fabrication techniques for microchannels. In this study, we established two fabrication methods for 3D microfluidic devices for the development of microscopic vessel models. First, we employed an exposure method using photolithographic technology. Second, we employed a 3D method using femtosecond laser and mask hybrid exposure (FMEx). Both methods made it possible to fabricate a millimeter-scale 3D structure with a submicrometer resolution and achieve an easy injection of solution. This is because it was possible to fabricate typical microfluidic channels used for model inlet and outlet ports. Furthermore, in the FMEx method, we employed an acid-diffusion effect using a chemically amplified resist to form a circular channel cross-section. The acid-diffusion effect made it realizable to fabricate a smooth surface independent of the laser scanning line width. Thus, we succeeded in establishing two methods for the fabrication of bionic 3D microfluidic devices with microfluidic channels having diameters of 15⁻16 µm for mimicking capillary vessels.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6187555PMC
http://dx.doi.org/10.3390/mi9030101DOI Listing

Publication Analysis

Top Keywords

vessel models
20
microscopic vessel
12
microfluidic devices
8
microfluidic channels
8
models
6
vessel
5
fabrication
4
fabrication capillary
4
capillary vessel
4
models circulatory
4

Similar Publications

Production of Hydrophobic Microparticles at Safe-To-Inject Sizes for Intravascular Administration.

Pharmaceutics

January 2025

Laboratory of Biointerface Chemistry, Department of Molecules and Materials, Faculty of Science and Technology, Technical Medical Centre and MESA+ Institute, University of Twente, 7522NB Enschede, The Netherlands.

Hydrophobic microparticles are one of the most versatile structures in drug delivery and tissue engineering. These constructs offer a protective environment for hydrophobic or water-sensitive compounds (e.g.

View Article and Find Full Text PDF

Background/objectives: Both hyperandrogenism (HA) and vitamin D deficiency (VDD) can separately lead to impaired vascular reactivity and ovulatory dysfunction in fertile females. The aim was to examine the early interactions of these states in a rat model of PCOS.

Methods: Four-week-old adolescent female rats were divided into four groups: vitamin D (VD)-supplemented ( = 12); VD-supplemented and testosterone-treated ( = 12); VDD- ( = 11) and VDD-and-testosterone-treated ( = 11).

View Article and Find Full Text PDF

Dual-Modal Approach for Ship Detection: Fusing Synthetic Aperture Radar and Optical Satellite Imagery.

Sensors (Basel)

January 2025

Department of Electrical and Software Engineering, University of Calgary, Calgary, AB T2N 1N4, Canada.

The fusion of synthetic aperture radar (SAR) and optical satellite imagery poses significant challenges for ship detection due to the distinct characteristics and noise profiles of each modality. Optical imagery provides high-resolution information but struggles in adverse weather and low-light conditions, reducing its reliability for maritime applications. In contrast, SAR imagery excels in these scenarios but is prone to noise and clutter, complicating vessel detection.

View Article and Find Full Text PDF

Aneurysmal subarachnoid hemorrhage (aSAH) carries significant mortality and disability rates, with rebleeding posing a grave risk, particularly in anterior communicating artery (AcoA) aneurysms. This retrospective study aims to analyze preoperative and intraoperative variables of patients with ruptured AcoA aneurysms, evaluating the association of these variables with patient outcomes using machine learning techniques, proposing a prognostic score. : A retrospective study was conducted on 50 patients who underwent microsurgical clipping for a ruptured AcoA aneurysm at San Giovanni Bosco Hospital, Turin, Italy.

View Article and Find Full Text PDF

: The development of microsurgical techniques has enabled reconstructive versatility in various clinical scenarios. Supermicrosurgery is an advanced microsurgical technique ensuring precise reconstructions by operating on small-caliber vessels and nerves, with applications in reconstructive surgeries. : This study aims to compare the effectiveness of four low-cost training models, thereby improving surgical precision and reducing the learning curve for novice surgeons.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!