In this biomechanical study, the strength of five different fixation techniques -anterior tension band wiring with K-wires, separate vertical wiring, headless compression screws with anterior tension band wiring, cannulated screws with tension band wiring and memory shape patellar fixator- for distal patellar fractures were compared. Forty calf knees were used for the biomechanical testing. Each specimen was pre-loaded with 10 N at 1 N/s. The distraction forces were applied consistently with the velocity of 5 mm/s. The ultimate load (N) and displacement (mm) values were recorded. The headless compression screw with anterior tension band wiring (656.9±167.9 N) and the cannulated screws with anterior tension band wiring (642.6±166.0 N) obtained significantly higher ultimate loading values compared to the other fixation methods (p<0.05). Fixation via cannulated screws with anterior tension band wiring techniques are more stabile than the patellar shape memory fixator and anterior K wire fixation.
Download full-text PDF |
Source |
---|
Handchir Mikrochir Plast Chir
January 2025
Hand Surgery, Baltalimani Special Hospital for Bone Diseases, Istanbul, Turkey.
Purpose: This study aims to compare the clinical and radiological outcomes of three different techniques used in the surgical treatment of ulnar styloid fractures.
Material And Method: Ulnar styloid fractures treated surgically between 2012 and 2022 were evaluated retrospectively. There were three groups in the study: Group I (Kirschner wire, N= 19), Group II (tension band, N= 27) and Group III (headless compression screw, N= 25).
J Orthop Case Rep
January 2025
Department of Orthopaedic Surgery, Dr. D Y Patil Hospital, Nerul, Navi Mumbai, Maharashtra, India.
Introduction: Post-operative complications related to hardware, particularly symptoms caused by it, such as implant impingement, wire breakage, and skin infection are frequently reported following surgical management of patellar fractures with stainless steel wires. As a potential solution, some researchers have advocated for the use of non-absorbable sutures for fracture fixation. This study aims to investigate the clinical and radiological outcomes of patients treated with fiber taping as an alternative technique.
View Article and Find Full Text PDFJ Orthop Case Rep
January 2025
Department of Orthopaedics, Calcutta National Medical College and Hospital, Kolkata, West Bengal, India.
Introduction: Olecranon fractures account for 5-7% of elbow fractures, making them a common injury. The majority of these fractures are treated surgically because they are intra-articular and can disrupt the elbow extensor mechanism. Mayo Type II fractures are displaced with a stable ulnohumeral joint, indicating intact ligamentous structures, particularly the anterior portion of the medial collateral ligament.
View Article and Find Full Text PDFCureus
January 2025
Orthopaedic Surgery, College of Medicine, King Saud University, Riyadh, SAU.
The traditional standard of care, tension band wire fixation modalities commonly used to treat non-comminuted olecranon fractures, are frequently associated with complications, with symptomatic hardware being the most common issue, often necessitating subsequent surgical procedures for hardware removal. We present a case of a young, active gentleman who sustained a simple olecranon fracture (Mayo type IIA) and underwent open reduction with the innovative all-suture non-metallic internal fixation procedure. We used a low-profile, cost-effective alternative fracture fixation technique, following the principles of pre-existing surgical techniques, while utilizing FiberWire sutures with biomechanical properties equivalent to, or possibly superior to, conventionally used metallic wires, thereby eliminating the need for additional surgical intervention.
View Article and Find Full Text PDFJ Phys Chem B
January 2025
Chemical, Biological and Macromolecular Sciences, S. N. Bose National Centre for Basic Sciences, J. D. Block, Sec.III, Salt Lake, Kolkata, West Bengal 700 098, India.
We investigated the temperature dependence of the intermolecular dynamics, including intermolecular vibrations and collective orientational relaxation, of one of the most typical deep eutectic solvents, reline, using femtosecond Raman-induced Kerr effect spectroscopy (fs-RIKES), subpicosecond optical Kerr effect spectroscopy (ps-OKES), and molecular dynamics (MD) simulations. According to fs-RIKES results, the temperature-dependent intermolecular vibrational band peak at ∼90 cm exhibited a redshift with increasing temperature. The density-of-state (DOS) spectrum of reline by MD simulations reproduced this fs-RIKES spectral feature.