Background: Donation after circulatory death (DCD) liver grafts are known to be predisposed to primary nonfunction and ischemic cholangiopathy. Many DCD grafts are discarded because of older donor age or long warm ischemia times. Thus, it is critical to improve the quality of DCD liver grafts. Here, we have tested whether an enriched oxygen carrier added to the preservation solution can prolong graft survival and reduce biliary damage.
Methods: We assessed the adenosine triphosphate (ATP) content decay of mouse liver grafts after cold ischemia, warm ischemia, and combined warm+cold ischemia. In addition, we used a rat model of liver transplantation to compare survival of DCD grafts preserved in high-oxygen solution (preoxygenated perfluorocarbon [PFC] + University of Wisconsin [UW] solution) versus lower oxygen solution (preoxygenated UW solution).
Results: Adenosine triphosphate levels under UW preservation fall to less than 10% after 30 minutes of warm ischemia. Preoxygenated UW solution with PFC reached a significantly higher PaO2. After 45 minutes of warm ischemia in oxygenated UW + PFC solution, grafts showed 63% higher levels of ATP (P = 0.011). In addition, this was associated with better preservation of morphology when compared to grafts stored in standard UW solution. Animals that received DCD grafts preserved in higher oxygenation solution showed improved survival: 4 out of 6 animals survived long-term whereas all control group animals died within 24 hours.
Conclusions: The additional oxygen provided by PFC during static cold preservation of DCD livers can better sustain ATP levels, and thereby reduce the severity of ischemic tissue damage. PFC-based preservation solution extends the tolerance to warm ischemia, and may reduce the rate of ischemic cholangiopathy.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/TP.0000000000002530 | DOI Listing |
Int J Med Robot
February 2025
Department of Surgery, Division of Transplantation, SUNY Upstate Medical University, Syracuse, New York, USA.
Background: We aimed to investigate the outcome of patients after RDN at different time points.
Methods: We studied the outcomes of 77 living robotic living donor nephrectomies (RDN). Donors were separated into three groups: learning curve period (LCP), stabilisation period (SP), and teaching period (TP).
Objective: To assess the efficacy of renal score grading in guiding therapy decisions, predicting perioperative outcomes, and characterising tumours following partial nephrectomy.
Methods: The retrospective, single-centre study was conducted at the University College Hospital Galway, Ireland, and comprised data from January 11, 2012, to June 17, 2016, of all patients aged >18 years who underwent partial nephrectomy as part of treatment for kidney cancer. Data was analysed using SPSS 20.
Transplant Proc
January 2025
Servicio de Urología, Hospital Universitario Cruces, Barakaldo, Bizkaia, Spain.
Introduction: The length of the right renal vein is a crucial vascular factor in kidney transplantation. Its shorter length compared to the left renal vein complicates venous anastomosis. The aim of this article is to review the literature on this topic and provide data from our experience.
View Article and Find Full Text PDFChin Med J (Engl)
January 2025
Key Laboratory of Hepatosplenic Surgery, Ministry of Education, Department of Minimal Invasive Hepatic Surgery, The First Affiliated Hospital of Harbin Medical University, Harbin, Heilongjiang 150001, China.
Background: Arsenic trioxide (ATO) is indicated as a broad-spectrum medicine for a variety of diseases, including cancer and cardiac disease. While the role of ATO in hepatic ischemia/reperfusion injury (HIRI) has not been reported. Thus, the purpose of this study was to identify the effects of ATO on HIRI.
View Article and Find Full Text PDFTransl Androl Urol
December 2024
Department of Urology, Peking University First Hospital Miyun Hospital, Beijing, China.
Background: The Toumai MT-1000 Endoscopic Surgical System is a newly developed surgical robot from China. This study evaluates its feasibility, safety, and effectiveness for various urologic procedures based on our single-center experience.
Methods: From October 2023 to January 2024, 20 urologic procedures were performed at Peking University First Hospital using the Toumai MT-1000 system.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!