A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Transmission of Staphylococcus aureus from dry surface biofilm (DSB) via different types of gloves. | LitMetric

Transmission of Staphylococcus aureus from dry surface biofilm (DSB) via different types of gloves.

Infect Control Hosp Epidemiol

1Surgical Infection Research Group, Faculty of Medicine and Health Sciences (FMHS), Macquarie University,Sydney,New South Wales,Australia.

Published: January 2019

Background: Pathogens can survive for extended periods when incorporated into biofilm on dry hospital surfaces (ie, dry-surface biofilm, DSB). Bacteria within biofilm are protected from desiccation and have increased tolerance to cleaning agents and disinfectants.

Objective: We hypothesized that gloved hands of healthcare personnel (HCP) become contaminated with DSB bacteria and hence may transmit bacteria associated with healthcare-associated infections (HAIs).

Method: Staphylococcus aureus DSB was grown in vitro on coupons in a bioreactor over 12 days with periodic nutrition interspersed with long periods of dehydration. Each coupon had ~107 DSB bacterial cells. Transmission was tested with nitrile, latex, and surgical gloves by gripping DSB-covered coupons then pressing finger tips onto a sterile horse blood agar surface for up to 19 consecutive touches and counting the number of colony-forming units (CFU) transferred. Coupons were immersed in 5% neutral detergent to simulate cleaning, and the experiment was repeated.

Results: Bacterial cells were readily transmitted by all 3 types of gloves commonly used by HCP. Surprisingly, sufficient S. aureus to cause infection were transferred from 1 DSB touch up to 19 consecutive touches. Also, 6 times more bacteria were transferred by nitrile and surgical gloves than to latex gloves (P <.001). Treating the DSB with 5% neutral detergent increased the transmission rate of DSB bacteria 10-fold.

Conclusion: Staphylococcus aureus incorporated into environmental DSB and covered by extracellular polymeric substances readily contaminates gloved hands and can be transferred to another surface. These results confirm the possibility that DSB contributes to HAI acquisition.

Download full-text PDF

Source
http://dx.doi.org/10.1017/ice.2018.285DOI Listing

Publication Analysis

Top Keywords

staphylococcus aureus
12
dsb bacteria
12
dsb
10
biofilm dsb
8
types gloves
8
gloved hands
8
bacterial cells
8
surgical gloves
8
consecutive touches
8
neutral detergent
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!