AI Article Synopsis

  • The study aims to evaluate how different clinical factors can predict infections or dysfunctions in tunneled hemodialysis catheters.
  • A total of 177 adult patients had their data analyzed, revealing that 9.6% experienced infections and 38.4% had dysfunctions leading to catheter removal or exchange, with significant differences in time-to-removal based on the type of issue.
  • Key findings indicated that female patients and left-sided catheter placements were associated with higher risks for complications compared to other factors.

Article Abstract

Purpose: To assess the ability of various clinical factors to predict infection or dysfunction of tunneled hemodialysis catheters.

Methods: A retrospective review of all adult patients who had a tunneled hemodialysis catheter placed between 2012 and 2016 was performed. Tunneled hemodialysis catheters were considered infected based on clinical suspicion or culture-positive bacteremia. Dysfunction was defined as all other non-infectious causes for line failure. Time-to-removal or exchange was recorded. Clinical parameters analyzed as potential predictors of tunneled hemodialysis catheter infection or dysfunction, included the following: age, sex, site of placement, inpatient versus outpatient status at time of placement, body mass index, Charlson Comorbidity Index, neutrophil-to-lymphocyte ratio, platelet-to-lymphocyte ratio, platelet count, white blood cell count, international normalized ratio, and partial thromboplastin time.

Results: A total of 177 patients (95: female, 82: male; 71.7%: African American; mean age: 54.9 years) qualified for inclusion. The internal jugular vein was the site of placement in 97.1% of patients with 79.7% of lines being placed on the right side. One patient (0.5%) had minor bleeding after catheter insertion but no other complications were recorded. A total of 17 patients (9.6%) had lines removed or exchanged due to infection at a median of 86 (range: 13-626) days, while 68 patients (38.4%) had lines removed or exchanged due to dysfunction at a median of 42 (range: 1-531) days. A total of 92 patients (51.9%) had lines removed due to completion of therapy at a median of 68 (range: 7-433) days. Dysfunctional lines had a shorter time-to-removal than successful lines ( = 0.007). No difference was seen in time-to-removal between infected lines and successful lines ( = 0.16). Multivariate analysis showed that female sex ( = 0.003) and left-sided line placement ( = 0.007) were independent predictors of line dysfunction. No evaluated factors were predictive of tunneled hemodialysis catheter infection.

Conclusion: Female sex and left-sided line placement were independent predictors of tunneled hemodialysis catheter dysfunction, but none of the evaluated parameters predicted tunneled hemodialysis catheter infection.

Download full-text PDF

Source
http://dx.doi.org/10.1177/1129729818809669DOI Listing

Publication Analysis

Top Keywords

tunneled hemodialysis
32
hemodialysis catheter
24
predictors tunneled
12
catheter infection
12
infection dysfunction
12
lines removed
12
median range
12
potential predictors
8
tunneled
8
hemodialysis
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!