Tricuspid regurgitation in the context of hypoplastic left heart syndrome (HLHS) carries a significant burden of both mortality and morbidity. We report successful hybrid trans-atrial implantation of an Edwards Sapien XT valve into a dysfunctional bioprosthetic valve in the tricuspid position of a 9-year-old patient with HLHS. There was an immediate fall in the Fontan pressures combined with significant clinical improvement and the valve continues to function well nearly 3 years post implant. To the best of our knowledge, this is the first described implantation of a transcatheter valve in this specific position and anatomy.

Download full-text PDF

Source
http://dx.doi.org/10.1002/ccd.27910DOI Listing

Publication Analysis

Top Keywords

edwards sapien
8
sapien valve
8
hypoplastic left
8
left heart
8
heart syndrome
8
valve
5
hybrid transcatheter
4
transcatheter tricuspid
4
tricuspid valve-in-valve
4
valve-in-valve placement
4

Similar Publications

Background: Transcatheter aortic valve implantation (TAVI) is a safe and effective therapy for patients with severe aortic stenosis. A Stuck leaflet and severe intraprosthetic regurgitation after valve implantation occur rarely but can lead to sudden haemodynamic deterioration. We encountered a case of a stuck leaflet following post-dilatation with the Edwards Sapien 3 Ultra RESILIA valve.

View Article and Find Full Text PDF

Background: Transcatheter aortic valve implantation (TAVI) has shown similar or improved clinical outcomes compared with surgical aortic valve replacement (SAVR) in patients with symptomatic severe aortic stenosis at low risk for surgical mortality. This cost-utility analysis compared TAVI with SAPIEN 3 versus SAVR in symptomatic severe aortic stenosis patients at low risk of surgical mortality from the perspective of the Swedish healthcare system.

Methods: A published, two-stage, Markov-based cost-utility model that captured clinical outcomes from the (SWEDEHEART) registry (2018-2020) was adapted from the perspective of the Swedish healthcare system using local general population mortality, utility and costs data.

View Article and Find Full Text PDF

Background: The Edwards Sapien percutaneous valve (Edwards Lifesciences, Irvine, CA, USA) is a promising therapeutic option for congenital atrioventricular disease mostly because of the possibility to accommodate somatic growth with balloon dilatation.

Case Summary: This article reports the performance of the Edwards Sapien 3 valve in atrioventricular valve position in four paediatric patients.

Discussion: Despite aggressive antiplatelet and anticoagulation strategies, most patients showed early bioprosthesis dysfunction, with increasing gradient not related with somatic growth.

View Article and Find Full Text PDF

Background: Balloon-assisted bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction (BA-BASILICA) enables valve-in-valve transcatheter aortic valve implantation (ViV-TAVI) in patients at risk of coronary artery obstruction. However, its efficacy in patients with severely calcified leaflets remains unclear.

Case Summary: We report a 78-year-old woman with a deteriorated 21 mm Carpentier-Edwards PERIMOUNT Magna valve.

View Article and Find Full Text PDF

Background: No data compare newer-generation transcatheter heart valves (THVs) in terms of next-day discharge (NDD) following transfemoral (TF) transcatheter aortic valve implantation (TAVI).

Aims: We aimed to evaluate the safety of NDD in unselected patients who received ACURATE (neo/neo2), Evolut (PRO/PRO+/FX) and the SAPIEN (3/Ultra) THVs.

Methods: This multicentre registry included patients who underwent TF-TAVI without a preprocedural permanent pacemaker implantation (PPI) and were discharged the next day without a new PPI.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!