Fracture-dislocations of the fourth and fifth carpometacarpal (CMC) joints present a complex situation. Misdiagnosis and inadequate treatment may cause malunion and residual subluxation, which lead to painful arthritis and grip weakness. Open reduction along with internal fixation is the treatment of choice, but there is no consensus on an optimal treatment approach. We applied a novel surgical technique to treat a case of a fracture-dislocation of the fifth CMC joint with avulsion fracture of the hamate using a dorsal buttress plate between the hamate and the capitate. This method allowed for achieving rigid fixation without screw insertion across the bone fragments of the hamate. We could avoid the risk of unexpected fragmentation and unexpected damage to the volar neurovascular bundles around the hook of the hamate. Six months postoperatively, bone union was achieved and the reduction of the fourth and fifth CMC joints was maintained. Range of motion of the fourth and fifth CMC joints was almost equal to that on the contralateral side. Dorsal buttress plating between the hamate and the capitate could be an alternative technique for the treatment of fracture-dislocation of the fifth CMC joint with avulsion fracture of the hamate.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00402-018-3072-0DOI Listing

Publication Analysis

Top Keywords

dorsal buttress
12
joint avulsion
12
avulsion fracture
12
fracture hamate
12
cmc joints
12
buttress plate
8
fixation treatment
8
treatment fracture-dislocation
8
fracture-dislocation cmc
8
cmc joint
8

Similar Publications

Background: Trimming is critical for a functioning equine hoof. Pressure distribution provides information on loading; however, information on the effects of trimming on pressure distribution is lacking.

Objectives: To describe the pressure changes of equine fore feet following trimming.

View Article and Find Full Text PDF

Background: Extra-articular but severely comminuted distal basal fractures of the proximal phalanx (PP) are rarely reported. Therefore, the aim of this study was to achieve proper union and desirable outcomes using low-profile locking plates/screws. We introduced our own surgical approach and reported the clinical/radiographic outcomes via retrospective case series.

View Article and Find Full Text PDF
Article Synopsis
  • The use of titanium cable cerclage for additional support in plate osteosynthesis of distal femoral fractures shows promise in improving fracture stability and load-bearing capacity compared to traditional steel wire cerclage.
  • A study involved creating unstable fractures in nonosteoporotic cadaver femora and testing the strength of their fixations, revealing that titanium cerclage specimens withstood higher failure loads than those without it.
  • However, both methods faced failure primarily due to distal screw issues, and no significant differences were noted in stiffness or deformity between the two fixation methods.
View Article and Find Full Text PDF

Dorsal spanning plates are frequently utilized to manage comminuted intra-articular distal radius fractures, but there is little literature on combining them with augmented fixation in complex cases. We present a 43-year-old man who fell 5 ft onto his outstretched right hand. On examination, there was gross swelling and tenderness of the right wrist with no neurovascular deficit.

View Article and Find Full Text PDF

Introduction: Barton fractures are distal radius fractures that extend through the dorsal aspect of the articular surface, with associated dislocation of the radiocarpal joint. They are extremely unstable and require open reduction and internal fixation (ORIF). Delayed presentation is often encountered with difficulty in achieving reduction, and more extensive surgery may be needed.