Background: General anesthesia (GA) or sedation has been used to obtain good-quality motion-free breath-hold chest CT scans in young children; however pulmonary atelectasis is a common and problematic accompaniment that can confound diagnostic utility. Dual-source multidetector CT permits ultrafast high-pitch sub-second examinations, minimizing motion artifact and potentially eliminating the need for a breath-hold.

Objective: The purpose of this study was to evaluate the feasibility of free-breathing ultrafast pediatric chest CT without GA and to compare it with breath-hold and non-breath-hold CT with GA.

Materials And Methods: Young (≤3 years old) pediatric outpatients scheduled for chest CT under GA were recruited into the study and scanned using one of three protocols: GA with intubation, lung recruitment and breath-hold; GA without breath-hold; and free-breathing CT without anesthesia. In all three protocols an ultrafast high-pitch CT technique was used. We evaluated CT images for overall image quality, presence of atelectasis and motion artifacts.

Results: We included 101 scans in the study. However the GA non-breath-hold technique was discontinued after 15 scans, when it became clear that atelectasis was a major issue despite diligent attempts to mitigate it. This technique was therefore not included in statistical evaluation (86 remaining patients). Overall image quality was higher (P=0.001) and motion artifacts were fewer (P<.001) for scans using the GA with intubation and recruitment technique compared to scans in the non-GA free-breathing group. However no significant differences were observed regarding the presence of atelectasis between these groups.

Conclusion: We demonstrated that although overall image quality was best and motion artifact least with a GA-breath-hold intubation and recruitment technique, free-breathing ultrafast pediatric chest CT without anesthesia provides sufficient image quality for diagnostic purposes and can be successfully performed both without and with contrast agent in young infants.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00247-018-4295-5DOI Listing

Publication Analysis

Top Keywords

ultrafast pediatric
8
pediatric chest
8
young children
8
ultrafast high-pitch
8
three protocols
8
image quality
8
breath-hold
5
ultrafast
4
chest
4
chest computed
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!