Ten-year experience of tricuspid valve replacement with the St. Jude medical valve.

Sci Rep

Department of Cardiovascular Surgery, West China Hospital, Sichuan University, Chengdu, Sichuan, P. R. China.

Published: November 2018

Bioprosthetic valves for tricuspid valve replacement (TVR) have become increasingly popular in recent years, but mechanical valves remain valuable, particularly for the patients who want to avoid reoperation for bioprostheses malfunction. The aim of this study was to review our 10-year experience in adult patients who underwent TVR with the St. Jude Medical (SJM) valve. From 2005 to 2015, 265 TVRs with SJM valves were performed at our institution. The mean age at operation was 44.1 ± 9.7 years, and 207 cases (78.1%) were female. The mean follow-up was 4.9 ± 2.7 years. Preoperative atrial fibrillation was present in 199 cases (75.1%) and ascites in 26 (9.8%). Of all cases, 88.7% were characterized as New York Heart Association class III or IV. The hospital mortality was 6.4%. There were 9 deaths (3.8%) during late follow-up. The overall survival rates were 89.2% ± 2.2% at 5 years and 86.6% ± 2.9% at 10 years. The linearized rates of valve thrombosis and bleeding events were 0.8%/patient-year and 1.5%/patient-year, respectively. Three cases (1.3%) were reoperated due to prosthetic valve thrombosis. There was no reoperation for sperivalvular leakage and structural failure. The freedom from reoperation was 98.6% ± 0.8% at 5 years and 98.6% ± 0.8% at 10 years. The SJM valve in the tricuspid position is a reliable mechanical prosthesis with a low rate of valve thrombosis and reoperation. It is a reasonable choice for the patients who require mechanical valve replacement in the tricuspid position.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6226498PMC
http://dx.doi.org/10.1038/s41598-018-35142-8DOI Listing

Publication Analysis

Top Keywords

valve replacement
12
valve thrombosis
12
valve
9
tricuspid valve
8
jude medical
8
sjm valve
8
thrombosis reoperation
8
986% ± 08% years
8
tricuspid position
8
years
7

Similar Publications

Transfemoral transcatheter aortic valve Replacement (TAVR) has become the standard therapy for patients with severe aortic stenosis in patients over 75 years old in Europe or 65 years old in the United States, regardless of the surgical risk. Furthermore, iterations of existing transcatheter aortic valves (TAVs), as well as devices with novel concepts, have provided substantial improvements with respect to the limitations of previous-generation devices. Hence, treatment of a broader spectrum of patients has become feasible, and a sophisticated selection of the appropriate TAV tailored to patients' anatomy and comorbidities is now possible.

View Article and Find Full Text PDF

The Ross procedure continues to be the best procedure to address unrepairable aortic valve pathology, especially in young adults. The Achilles heel of this procedure has been aortic root dilation and the potential need for a reoperation that may be associated with slightly increased risks in addition to the need for intervention on the pulmonary outflow tract. Modifying the Ross procedure by autograft inclusion inside a Dacron graft seems to have the potential advantage of stabilizing the autograft diameter, which may be associated with improved durability and decrease the need for future intervention.

View Article and Find Full Text PDF

Background: A staging system based on cardiac damage for severe aortic stenosis (AS) has been validated for prognosis prediction following transcatheter aortic valve replacement (TAVR). Our study aims to investigate whether TAVR can lead to changes in cardiac damage shortly after the procedure and how these changes impact prognosis.

Method: Patients in this retrospective cohort study were classified into five stages (0-4) before TAVR based on the echocardiographic findings of cardiac damage.

View Article and Find Full Text PDF

ECMO in the Cardiac Catheterization Lab-Patient Selection Is Key.

J Cardiovasc Dev Dis

December 2024

Department of Cardiothoracic and Vascular Surgery, Montefiore Medical Center, Bronx, NY 10467, USA.

The use of extracorporeal membrane oxygenation (ECMO) has emerged as a rescue intervention for hemodynamically unstable patients and prophylactic intraprocedural hemodynamic support in the cardiac catheterization laboratory. The prompt initiation of ECMO provides immediate hemodynamic support and allows for the completion of bridging and/or life-saving interventions. However, there are no clinical practice guidelines for the use of extracorporeal support in this area.

View Article and Find Full Text PDF

Transcatheter aortic valve replacement (TAVR) in patients with severe aortic stenosis and raphe-type bicuspid aortic valve (BAV) is still associated with poor outcomes in terms of increased risk of paravalvular regurgitation, stroke, and permanent pacemaker implantation. There is no definitive consensus on the optimal sizing method for prosthesis selection in this setting. The LIRA method is a supra-annular tailored sizing method specifically designed for bicuspid anatomy that might increase accuracy of prosthesis choice in BAV patients and improve TAVR outcomes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!