Context: Anatomical literature has described the anterior loop being an extension of the mental nerve which is present anterior to the mental foramen while the caudal loop has been described as the distance between the lower border of the mental foramen and the lowest point of the mandibular canal. The knowledge and identification of the anterior and caudal loop of the mental nerve are important in surgical procedures performed around the mental foramen to avoid inadvertent damage to these vital structures resulting in postoperative complications.

Aim: The present study was conducted to determine the incidence and measurement of mental nerve loop in the mandibular arches using cone beam computed tomography (CBCT).

Settings And Design: A total of 200 CBCT images were retrieved and inspected for the presence of the mental nerve loop. The length of the anterior loop was measured by counting the number of consecutive contiguous vertical cross sections displaying two round hypodense images. This number was multiplied by the thickness of the slices. The caudal loop was measured as the distance between the lower border of the mental foramen and the lowest point of mandibular canal.

Statistical Analysis Used: Shapiro-Wilk test and Mann-Whitney U-test were used. P < 0.05 was considered statistically significant.

Results: 57.5% (n = 200 scans) presented with the anterior loop of the mental nerve with a mean length of 0.50 mm and 0.37 mm on the right side and left side, respectively. All the samples of CBCT scans taken were having caudal loop extension with a mean length of 3.53 mm.

Conclusion: A considerable number of individuals (57.5%) in the present study presented with the anterior loop of the mental nerve. CBCT was found to be an effective imaging modality for the detection of anterior loop of the mental nerve.

Download full-text PDF

Source
http://dx.doi.org/10.4103/ijdr.IJDR_50_17DOI Listing

Publication Analysis

Top Keywords

mental nerve
32
anterior loop
20
mental foramen
16
caudal loop
16
loop mental
16
mental
12
loop
12
nerve loop
12
nerve
8
cone beam
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!