Taking advantage of the low oxidation potential of polyphenolic compounds, voltammetric techniques, such as cyclic voltammetry (CV) and differential pulse voltammetry (DPV) are used rather indiscriminately. In this work, we report Total Polyphenols results (TPP) obtained by these two techniques from a set of nine samples of red and Tawny Port wine. The CV and DPV voltammograms display significant correlations with the physical-chemical parameters used to characterize red and Tawny Port wines, particularly with polyphenols. Although data obtained from CV and DPV for a single polyphenol are directly proportional, important deviations are found between voltammetric results from wines. Results from CV tend to be larger than those from DPV. This difference, that can reach 50% of the TPP value, was related to the presence of total sulphur dioxide. In view of the present study, the polyphenol quantification in wines should be performed by DPV to minimize the interference of SO.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.foodchem.2018.10.078 | DOI Listing |
ACS Sens
January 2025
Department of Chemistry, Burke Laboratories, Dartmouth College, 41 College St., Hanover, New Hampshire 03755, United States.
This paper describes the first use of conductive metal-organic frameworks as the active material in the electrochemical detection of nitric oxide in aqueous solution. Four hexahydroxytriphenylene (HHTP)-based MOFs linked with first-row transition metal nodes (M = Co, Ni, Cu, Zn) were compared as thin-film working electrodes for promoting oxidation of NO using voltammetric and amperometric techniques. Cu- and Ni-linked MOF analogs provided signal enhancement of 5- to 7-fold over a control glassy carbon electrode (SA = 6.
View Article and Find Full Text PDFAnal Methods
January 2025
Department of Nutrition and Dietetics, Faculty of Health Sciences, Hasan Kalyoncu University, Gazi-antep, 27000, Turkey.
In the present study, a novel voltammetric sensor based on a boron-doped copper oxide/graphene (B-CuO-Gr) nanocomposite and molecularly imprinted polymer (MIP) was developed for the detection of paclobutrazol (PAC) in apple and orange juice samples. The B-CuO-Gr nanocomposite was prepared using sol-gel and calcination methods. After modifying glassy carbon electrodes with the B-CuO-Gr nanocomposite, PAC-imprinted electrodes were prepared in the presence of 100.
View Article and Find Full Text PDFFoods
January 2025
School of Food and Biological Engineering, Engineering Research Center of Bio-Process of Ministry of Education, Anhui Province Laboratory of Agricultural Products Modern Processing, Hefei University of Technology, Hefei 230009, China.
Due to their lipophilicity and low content, the major sesame oleosin allergens, Ses i 4 and Ses i 5, are challenging to identify using conventional techniques. Then, a novel unlabeled electrochemical immunosensor was developed to detect the potential allergic activity of sesame oleosins. The voltammetric immunosensor was constructed using a composite of gold nanoparticles (AuNPs), polyethyleneimine (PEI), and multi-walled carbon nanotubes (MWCNTs), which was synthesized in a one-pot process and modified onto a glass carbon electrode to enhance the catalytic current of the oxygen reduction reaction.
View Article and Find Full Text PDFAnal Chim Acta
January 2025
Department of Chemistry and Biochemistry, Utah State University, 0300 Old Main Hill, Logan, UT, 84322, USA; Department of Chemistry, University of Louisiana at Lafayette, 300 East St. Mary Blvd, Lafayette, LA, 70504, USA. Electronic address:
A rapid and accurate biosensor for detecting disease biomarkers at point-of-care is essential for early disease diagnosis and preventing pandemics. CRISPR-Cas12a is a promising recognition element for DNA biosensors due to its programmability, specificity, and deoxyribonuclease activity initiated in the presence of a biomarker. The current electrochemical CRISPR-Cas12a-based biosensors utilize the single-stranded DNA (ssDNA) self-assembled on an electrode surface and covalently modified with the redox indicator, usually methylene blue (MB).
View Article and Find Full Text PDFMicroorganisms
December 2024
Biosensor Research Institute, Seoul National University of Science & Technology, Seoul 01811, Republic of Korea.
The WHO has classified Helicobacter pylori as a group 1 carcinogen for stomach cancer since early 1994. However, despite the high prevalence of Helicobacter pylori infection, only about 3% of infected people eventually develop gastric cancer.Biomolecular detections of Helicobacter pylori(HP) were compared using specially modified sensors and fluorine immobilized on a carbon nanotube (HFCNT) electrode, which yielded sensitive results.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!