We report the case of a stent under-expansion due to heavily calcified plaque treated with the shockwave lithoplasty system. A 77-year-old woman underwent coronary angiography, and intravascular ultrasound revealed stent under-expansion due to calcified plaque. Shockwave lithoplasty balloon was used to disrupt calcium deposits around the stent, thereby allowing a correct stent expansion with an excellent angiographic and intravascular ultrasound result.

Download full-text PDF

Source
http://dx.doi.org/10.1159/000493747DOI Listing

Publication Analysis

Top Keywords

stent under-expansion
12
calcified plaque
12
shockwave lithoplasty
12
case stent
8
under-expansion calcified
8
plaque treated
8
treated shockwave
8
intravascular ultrasound
8
lithoplasty report
4
report case
4

Similar Publications

Coronary calcification is a major factor leading to stent under-expansion, and subsequent adverse events. This meta-analysis aimed to evaluate the short and long‑term outcomes of rotational atherectomy (RA), followed by modified balloon (cutting or scoring) (MB) versus plain balloon before drug‑eluting stent implantation for calcified coronary lesions. We searched PubMed, Web of Science (WOS), Scopus, and the Cochrane Library Central Register of Controlled Trials (CENTRAL), from inception until 30 January 2024.

View Article and Find Full Text PDF

[The modified hugging balloon technique].

G Ital Cardiol (Rome)

November 2024

S.C. Cardiologia, Ospedale S.G. Bosco, ASL Città di Torino, Torino.

Article Synopsis
  • Percutaneous coronary intervention (PCI) has greatly improved treatments for coronary artery disease, but in-stent restenosis (ISR) remains a significant issue, especially when complicated by calcification.
  • Various techniques exist for treating calcified ISR, including super-high-pressure balloon dilation, atherectomy methods, and intravascular lithotripsy (IVL).
  • This case report discusses a patient with severe, calcified ISR in a large artery, showcasing the use of shockwave lithotripsy combined with balloon dilation to improve stent expansion, highlighting the effectiveness of innovative approaches for difficult ISR cases.
View Article and Find Full Text PDF

Coronary artery calcification is frequently encountered during percutaneous coronary intervention and its presence is associated with a higher risk of stent under-expansion which has been associated with long-term risk of stent failure. There are several different calcium modification strategies available, whether they be balloon-based devices (cutting/scoring and intravascular lithotripsy) or atherectomy devices (orbital atherectomy, rotational atherectomy, excimer laser coronary atherectomy) that are established for the modification of coronary calcification. Each strategy applies a different mechanism of action for calcium modulation and consequently the potential to combine modifying tools may offer synergistic advantages over device monotherapy.

View Article and Find Full Text PDF
Article Synopsis
  • Stent under-expansion can increase risks like neoatherosclerosis and stent thrombosis, especially in cases of severe coronary calcification, and intravascular lithotripsy (IVL) can help prevent this by ensuring proper stent expansion.
  • A 62-year-old male with unstable angina was treated for high-grade stenosis in the right coronary artery but experienced stent under-expansion despite multiple attempts to dilate it, including using ultra-high-pressure balloons.
  • The successful use of IVL led to complete stent expansion at a lower pressure, illustrating its effectiveness and safety in treating stent under-expansion, which is critical for preventing complications like restenosis and thrombosis.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!