A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Prevalence and quantification of contamination of knitted cotton outer gloves during hip and knee arthroplasty surgery. | LitMetric

Introduction: Knitted cotton outer gloves offer protection against surgical glove perforation and provide improved grip on instruments. These gloves absorb blood and other fluids during surgery, and may therefore also accumulate contaminating bacteria. To date, there is no published data on microbial contamination of such gloves during surgery.

Methods: Knitted cotton outer gloves used in primary and revision hip and knee arthroplasty from two Swiss hospitals were analysed by quantitative bacteriology. Samples were subjected to sonication and vortexing, followed by membrane filtration of the sonicate. Membranes were incubated under aerobic and anaerobic culture conditions, respectively, for 21 days. Total microbial load for each pair of gloves was determined by colony-forming units (CFU) count. Strain identification was performed with MALDI-TOF.

Results: A total of 43 pairs of gloves were collected from continuous series of surgeries. Under aerobic culture conditions, total CFU counts ranged 0-1103, 25 (58%) samples remaining sterile, and 4 (9%) yielding > 100 CFU. Under anaerobic culture conditions, total CFU counts ranged 0-3579, 22 (51%) samples remaining sterile, 6 (14%) yielding > 100 CFU. The only covariate significantly associated with the level of contamination was the provider hospital (p < 0.0001 for aerobic and p = 0.007 for anaerobic cultures). Strain identification revealed only skin commensals, mainly coagulase-negative staphylococci and Propionibacterium spp.

Conclusion: While contamination of surgical latex gloves is a well-known issue, no study has examined so far contamination of knitted cotton outer gloves. No or very low microbial contamination could be identified in the majority of the knitted cotton outer gloves assayed. However, a relevant proportion showed contamination far higher than estimated minimal thresholds for implant-associated infection. Clinical relevance of these findings remains to be established.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00402-018-3061-3DOI Listing

Publication Analysis

Top Keywords

knitted cotton
12
cotton outer
12
outer gloves
12
culture conditions
12
hip knee
8
knee arthroplasty
8
anaerobic culture
8
conditions total
8
total cfu
8
cfu counts
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!